Super Purchasing for TU-1F04 thermal wax actuator for air conditioner and compressor Wholesale to Indonesia

Super Purchasing for
 TU-1F04 thermal wax actuator for air conditioner and compressor Wholesale to Indonesia

Short Description:

Product Detail

Product Tags

We have been also concentrating on enhancing the things management and QC method so that we could preserve terrific edge inside the fiercely-competitive enterprise for Air Compressor Parts Filter , Rad Valves , Paraffin Wax Actuator , Quality is factory's life , Focus on customers' demand is the source of company survival and development, We adhere to honesty and good faith working attitude, looking forward to your coming !
Super Purchasing for TU-1F04 thermal wax actuator for air conditioner and compressor Wholesale to Indonesia Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Super Purchasing for
 TU-1F04 thermal wax actuator for air conditioner and compressor Wholesale to Indonesia detail pictures


Being supported by an highly developed and specialist IT team, we could give technical support on pre-sales & after-sales service for Super Purchasing for TU-1F04 thermal wax actuator for air conditioner and compressor Wholesale to Indonesia, The product will supply to all over the world, such as: New York , Poland , Dubai , We have got constantly insisted on the evolution of solutions, spent good funds and human resource in technological upgrading, and facilitate production improvement, meeting the wants of prospects from all countries and regions.



  • Diesel Fuel Volume Control Valve (VCV)

    Amazon Printed Books

    https://www.createspace.com/3786463

    Amazon Kindle Edition

    https://www.amazon.com/Diesel-Common-Injection-Automotive-ebook/dp/B00760D04U/ref=sr_1_2?s=digital-text&ie=UTF8&qid=1360015278&sr=1-2&keywords=diesel+injection%2C+mandy+concepcion

    Android APPs

    https://play.google.com/store/apps/details?id=com.app.book.AOTOTCCBNDTAEVFWAM&feature=search_result#?t=W251bGwsMSwxLDEsImNvbS5hcHAuYm9vay5BT1RPVENDQk5EVEFFVkZXQU0iXQ..

    Describes the operation of the volume control valve on diesel engines. The VCV is part of the main fuel injection pump. Fuel mixture is controlled by the VCV and PCV or pressure control valve. This is typical on many Diesel engines, including Navistar International and FORD engines. The VCV is a duty cycle controlled valve, which control the actual fuel volume. It works in tandem with the fuel rail pressure sensor.

    **************************************************************************************

    Amazon Printed-Books & Kindle:

    https://www.amazon.com/s/ref=nb_sb_noss_1?url=search-alias%3Dstripbooks&field-keywords=mandy+concepcion

    Google Play Android APPs:

    https://play.google.com/store/search?q=mandy+concepcion&c=apps

    Amazon Video DVDs:

    https://www.amazon.com/s/ref=nb_sb_noss_1?url=search-alias%3Dmovies-tv&field-keywords=mandy+concepcion

    Barnes & Noble Nook:

    https://www.barnesandnoble.com/s/mandy-concepcion?keyword=mandy+concepcion&store=allproducts

    Apple iTunes iPad:

    https://itunes.apple.com/us/artist/mandy-concepcion/id449573393?mt=11



    Check us out at https://physics.tutorvista.com

    How to Calibrate a Thermometer

    Thermometers can be calibrated either by comparing them with other certified thermometers or by checking them against known fixed points on the temperature scale. The best known of these fixed points are the melting and boiling points of pure water. (Note that the boiling point of water varies with pressure, so this must be controlled.)
    The traditional method of putting a scale on a liquid-in glass or liquid-in-metal thermometer was in three stages:
    1.Immerse the sensing portion in a stirred mixture of pure ice and water and mark the point indicated when it had come to thermal equilibrium.
    2.Immerse the sensing portion in a steam bath at 1 standard atmosphere (101.3 kPa; 760.0 mmHg) and again mark the point indicated.
    3.Divide the distance between these marks into equal portions according to the temperature scale being used.
    Other fixed points were used in the past are the body temperature (of a healthy adult male) which was originally used by Fahrenheit as his upper fixed point (96 °F (36 °C) to be a number divisible by 12) and the lowest temperature given by a mixture of salt and ice, which was originally the definition of 0 °F (−18 °C). (This is an example of a Frigorific mixture). As body temperature varies, the Fahrenheit scale was later changed to use an upper fixed point of boiling water at 212 °F (100 °C).
    These have now been replaced by the defining points in the International Temperature Scale of 1990, though in practice the melting point of water is more commonly used than its triple point, the latter being more difficult to manage and thus restricted to critical standard measurement. Nowadays manufacturers will often use a thermostat bath or solid block where the temperature is held constant relative to a calibrated thermometer. Other thermometers to be calibrated are put into the same bath or block and allowed to come to equilibrium, then the scale marked, or any deviation from the instrument scale recorded. For many modern devices calibration will be stating some value to be used in processing an electronic signal to convert it to a temperature.

    Please like our facebook page
    https://www.facebook.com/tutorvista Follow us at: https://plus.google.com/+tutorvista/

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the House

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    WhatsApp Online Chat !