13 Years Manufacturer TU-1C06 thermal wax actuator for thermostatic automatic water drain valve Wholesale to Switzerland

13 Years Manufacturer
 TU-1C06 thermal wax actuator for thermostatic automatic water drain valve Wholesale to Switzerland

Short Description:

Product Detail

Product Tags

Our enterprise since its inception, constantly regards product good quality as organization life, constantly improve production technology, strengthen merchandise high quality and continuously strengthen enterprise total good quality administration, in strict accordance with all the national standard ISO 9001:2000 for Automatic Roof Vent Opener , Motorcycle Enriching Valve , Car Engine Thermostat , We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
13 Years Manufacturer TU-1C06 thermal wax actuator for thermostatic automatic water drain valve Wholesale to Switzerland Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

13 Years Manufacturer
 TU-1C06 thermal wax actuator for thermostatic automatic water drain valve Wholesale to Switzerland detail pictures


To regularly increase the management program by virtue from the rule of "sincerely, good religion and high quality are the base of enterprise development", we greatly absorb the essence of linked products internationally, and constantly produce new goods to satisfy the calls for of shoppers for 13 Years Manufacturer TU-1C06 thermal wax actuator for thermostatic automatic water drain valve Wholesale to Switzerland, The product will supply to all over the world, such as: Bangladesh , Serbia , Poland , When you are keen on any of our items following you view our product list, please feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we are able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our items by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.



  • For complete instructions and parts needed to fix your door locks and other related vacuum problems go here: https://mercedessource.com/problems/vacuum/123-chassis-vacuum-door-lock-failure

    In this video Kent demonstrates just one of the possible reasons why your W123 vacuum door locks might not be working. There could be many other reasons why your door locks are not working. Click on the link above to learn more.



    How To Use A Mitsubishi Air Conditioner Remote Control Guide

    https://www.rfohl.com/

    (610) 377-1098

    Mitsubishi split unit heating and cooling systems are a great way to keep the inside of your home or office comfortable all year round. These HVAC systems come with remote controls for setting the temperature and controlling the system. This video discusses the remote control.

    For more information or to see a ductless split unit system, please visit our showroom.
    R.F. Ohl
    400 Interchange Rd
    Lehighton, PA 18235
    (610) 377-1098

    Visit us on Facebook: https://www.facebook.com/rf.ohlfuel
    Visit us on Twitter: https://twitter.com/RF_Ohl
    Watch our other YouTube Videos: https://www.youtube.com/channel/UC3yXwPjcmP5xHidivNff_Ag

    Handling of the remote controller unit for your Mitsubishi A/C
    • The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the indoor unit.
    • When a button is pressed, one or two beeps will be heard from the indoor unit. If no sound is heard, operate again.
    • Use the remote controller carefully. If it is dropped, thrown or it gets wet, the remote controller may not operate.

    When installing the remote controller on a wall, etc.
    • Install the remote controller holder in a position where the signal reception sound (beep) can be heard from the indoor unit when the ON/OFF button is pressed.

    How to set the batteries and the current time in the Mitsubishi remote control device for your air conditioning system:
    1- Remove the front lid and insert batteries, then reattach the front lid. Insert the minus pole of the batteries first. Check if the polarity of the batteries is correct.
    2- Press the RESET button. If the RESET button is not pressed, the remote controller may not operate correctly.
    3- Press the CLOCK set button.
    4- Press the HR. and MIN. buttons (TIME SET buttons) to set the current time. Each time the HR button is pressed, the set time
    increases by 1 hour, and each time the MIN button is pressed, the set time increases by 1 minute.
    5- Press the CLOCK set button again and close the front lid.

    When the remote controller cannot be used (emergency operation)
    When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the EMERGENCY OPERATION switch.

    Press the EMERGENCY OPERATION switch.
    • Each time the EMERGENCY OPERATION switch is pressed, the unit will operate in order of EMERGENCY COOL MODE, EMERGENCY HEAT MODE and STOP MODE. However, when the EMERGENCY OPERATION switch is once pressed, the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE.

    To stop the emergency operation, press the EMERGENCY OPERATION switch once (in case of EMERGENCY HEAT MODE) or twice (in case of EMERGENCY COOL MODE).

    Related Search Phrases:
    Mitsubishi remote control air conditioner instructions
    Mitsubishi electric air conditioner remote control manual
    Mitsubishi air conditioner remote control replacement
    Mitsubishi air conditioner remote control app
    Mitsubishi air conditioner remote control symbols
    Mitsubishi inverter air conditioner remote controller manual
    how to use Mitsubishi air conditioner remote control
    Mitsubishi ac remote control
    Mitsubishi air conditioner remote control code

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !