18 Years Factory offer TU-1D03 thermal wax actuator for industrial thermostatic water regulations mixing valve for Rotterdam Factory

18 Years Factory offer
 TU-1D03 thermal wax actuator for industrial thermostatic water regulations mixing valve for Rotterdam Factory

Short Description:

Product Detail

Product Tags

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Thermal Actuator Adaptors , Paraffin Wax Price , Automatic Temperature Controller With Cooling System Project , We take quality as the foundation of our success. Thus, we focus on the manufacture of the best quality products. A strict quality management system has been created to ensure the quality of the products.
18 Years Factory offer TU-1D03 thermal wax actuator for industrial thermostatic water regulations mixing valve for Rotterdam Factory Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

18 Years Factory offer
 TU-1D03 thermal wax actuator for industrial thermostatic water regulations mixing valve for Rotterdam Factory detail pictures


With our leading technology also as our spirit of innovation,mutual cooperation, benefits and advancement, we'll build a prosperous future together with your esteemed organization for 18 Years Factory offer TU-1D03 thermal wax actuator for industrial thermostatic water regulations mixing valve for Rotterdam Factory, The product will supply to all over the world, such as: Oman , Qatar , Paraguay , They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.



  • BECK actuators will be on display at the WEFTEC 2014 exhibition in New Orleans from Sept 29-Oct 1. Please stop by booth #1239 or contact BECK directly at info@haroldbeck.com or (215) 968-4600.



    Click Here to Subscribe! https://youtube.com/carsntoys Website: https://carsntoys.net

    In this video we explore how to test and replace the EVAP pressure sensor P0450. If you’ve been following this channel you know we have a number of EVAP repair videos available. This video will add to that collection.

    Trouble code p0450 deals with an improper voltage signal from the EVAP pressure sensor to the ECM. This could be due to a bad harness connector, the pressure sensor or the EVAP canister vent control valve. (link below for this component)

    This sensor is used with a number of components in throughout the EVAP system. The EVAP control system pressure sensor is located in the purge line. The sensor detects pressure inside the purge line and modifies the voltage signal sent from the ECM. As the pressure increases the voltage rises. This sensor is used for on board diagnostics.

    Tools Used:
    Safety Glasses
    Digital Multi-Meter
    Vacuum Pump (Mityvac)
    10mm socket & ratchet to remove sensor from chassis.

    Additional EVAP repair videos:

    EVAP Canister Vent Control Valve P0446 – https://youtu.be/C1h-3W4SFgk

    EVAP Canister Purge Control Valve P0443 – https://youtu.be/4z9uUwc3iV8

    EVAP Canister Purge SOLENOID Valve P0443 – https://youtu.be/7ni-mjr1xeg

    EVAP Canister Purge Volume Control Valve P1445 – https://youtu.be/QnVUBYdFHGI

    Note:
    This video is being performed by an experienced tech. Any attempt to repair automotive parts and/or systems carries risk of personal injury. Always adhere and follow safe practices when working on vehicles. Such as, use safety glasses, jack stands, no loose clothing, etc. No guarantee or warranty is implied. Use the information in this video at your own risk.

    Publication, reproduction or distribution of this film is strictly prohibited.

    This was performed on a 1997 Nissan Maxima. Please check with your vehicle’s repair manual for testing parameters.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !