Factory best selling Thermostatic Wax Linearity Series for Plymouth Manufacturers
Short Description:
Product Detail
Product Tags
Factory best selling Thermostatic Wax Linearity Series for Plymouth Manufacturers Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
|
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
|
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility sAcid and Alkali |
Mechanical Impurity |
||
|
B-5-1 |
Liquid |
-20/-5 |
≥7 |
Non. |
Non. |
|
B0-1 |
Liquid |
-15/0 |
≥7 |
Non. |
Non. |
|
B5-1 |
Liquid |
-10/5 |
≥7 |
Non. |
Non. |
|
B15-1 |
Liquid |
0/15 |
≥7 |
Non. |
Non. |
|
B20-1 |
Semisolid |
5/20 |
≥7 |
Non. |
Non. |
|
B25-1 |
Semisolid |
10/25 |
≥7 |
Non. |
Non. |
|
B30-1 |
Semisolid |
15/30 |
≥7 |
Non. |
Non. |
|
B35-1 |
Semisolid |
20/35 |
≥7 |
Non. |
Non. |
|
B40-1 |
Powder, Slice , Column |
25/40 |
≥7 |
Non. |
Non. |
|
B45-1 |
Powder, Slice , Column |
30/45 |
≥7 |
Non. |
Non. |
|
B50-1 |
Powder, Slice , Column |
35/50 |
≥7 |
Non. |
Non. |
|
B55-1 |
Powder, Slice , Column |
40/55 |
≥7 |
Non. |
Non. |
|
B60-1 |
Powder, Slice , Column |
45/60 |
≥7 |
Non. |
Non. |
|
B65-1 |
Powder, Slice , Column |
50/65 |
≥7 |
Non. |
Non. |
|
B70-1 |
Powder, Slice , Column |
55/70 |
≥7 |
Non. |
Non. |
|
B75-1 |
Powder, Slice , Column |
60/75 |
≥7 |
Non. |
Non. |
|
B80-1 |
Powder, Slice , Column |
65/80 |
≥7 |
Non. |
Non. |
|
B85-1 |
Powder, Slice , Column |
70/85 |
≥7 |
Non. |
Non. |
|
B90-1 |
Powder, Slice , Column |
75/90 |
≥7 |
Non. |
Non. |
|
B95-1 |
Powder, Slice , Column |
80/95 |
≥7 |
Non. |
Non. |
Product detail pictures:

Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs for Factory best selling Thermostatic Wax Linearity Series for Plymouth Manufacturers, The product will supply to all over the world, such as: Spain , Cologne , Jamaica , We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.
LG Air Conditioner Single Split Heat Cool Professional Installation. LG HVAC systems offer a range of solutions that are cost efficient, quiet and attractive. They provide a smart alternative to both central HVAC and window-mounted air conditioners, and are available in a variety of configurations to suit different cooling and heating situations. Split Systems – These innovative systems are “split” into indoor and outdoor units. The interior units are available in several different units. The interior units are available in several different configurations: Art Cool, standard wall-mounted, Floor Standing and ceiling cassettes. All interior units have remote controls for easy use. Installation by a qualified HVAC contractor is safe and easy – no duct work or sheet metal is needed. Single, dual and tri-zone systems, as well as cooling only and heat pump models, are available. Mini-Split High Efficient Air Conditioners Single-Zone – LG Electronics’ products have led the global air conditioner market with excellent performance and innovative design. LSxxxHSV models, a brilliant new addition to LG’s lineup, are high-performance air conditioners with a high SEER inverter and excellent design. • Plasma air purifying system • Energy Saving • Self-cleaning indoor coil • Auto changeover • Gold Fin™ Anti-Corrosion • Jet Cool • Cooling/Heating/Fan Mode • Auto sleep mode • Ultra-quiet operation • Dehumidifying mode • Auto restart • 24-Hour on/off timer • Evaporator frost control • Built-in low ambient standard, down to 0ºF (cooling mode) • Manual power switch • Temperature display on indoor unit • Defrost control. Indoor and outdoor units included. A-1 Plumbing Supply Warehouse www.A1LY.com Stocking HVAC Distributor. Buy Today. Ship Today. Delivered To Your Door. Always Insist On The Genuine A-1 Plumbing Supply Warehouse. Pleasing You Means Success To Us.
https://www.rpm-powered.com
1. System error
2. Actual value feeler virtually
3. Actual value interior feeler console
4. Actual value outside temperature – feeler wasserkasten
5. Actual value outside temperature – feeler bumper
6. Actual value blowing out feeler floor space
7. Actual value blowing out feeler man Anstroemer
8. Display check
9. Actual digital value acknowledging potentiometer temperature flap
10. Target digital value temperature flap
11. Actual digital value acknowledging potentiometer A/C flap
12. Target digital value A/C flap
13. Actual digital value acknowledging potentiometer Fuss/Def flap
14. Target digital value Fuss/Def flap
15. Actual digital value acknowledging potentiometer ram air flap
16. Target digital value ram air flap
17. Driving speed (km/h) ( used on movie )
18. Actual value of the blower tension (volt)
19. Desired value of the blower tension (volt)
20. Actual value of the compressor/on-board tension (volt)
21. Number of low-voltage events
(not volatilely)
22. Switching status of the high pressure switch
23. Number of high pressure events (volatile)
24. Number of high pressure events (not volatile)
25. A/D value kickdown switch
26. A/D value hot light
27. Engine speed
28. Compressor number of revolutions
29. Coding
30. Software-Version
31. Software index
32. Potentiometer error counter temperature flap
33. Potentiometer error counter A/C flap
34. Potentiometer error counter Fuss/Def flap
35. Potentiometer error counter ram air flap
36. Temperature flap notice cold
37. Temperature flap notice warm
38. A/C flap notice closed
39. A/C flap notice opened
40. Fuss/Def flap notice Def
41. Fuss/Def flap notice foot
42. Ram air flap notice up
43. Ram air flap notice too
44. Operating cycle counter
45. Interior temperature counted (Ninc) dig
46. Outside temperature filtered (°C)
47. Outside temperature not filtered (°C)
48. ECOR
49. Coolant temperature
50. Service life in min
51. Engine temperature °C
52. Compressor switching off conditions
53. Announcement more actively el. Exits:
Compressor/circulating air valve/water valve
54. Rule index
55. Outside temperature °C
56. Interior feeler virtually °C
57. Interior feeler console °C
58. Temperature wasserkasten °C
59. Temperature bumper °C
60. Blowing out feeler floor space °C
61. Blowing out feeler man Anstroemer °C
62. Sun intensity W/m-1
63. Sun intensity filtered W/m-1
64. Delta exhaust rise
65. Delta A/C Klappenverschiebung
66. Time constant/1.6 seconds
67. Cold weather starting correction
68. Maximum correcting variable for i and p-portion
69. Actual value blowing out feeler foot (cnts)
70. Desired value blowing out feeler foot (cnts)
71. Deviation (Epsilon)
72. Portion (+ heat/- cool)