Factory best selling TU-026D thermostatic cartridge wax sensor for sanitary ware to Denver Importers

Factory best selling
 TU-026D thermostatic cartridge wax sensor for sanitary ware  to Denver Importers

Short Description:

Product Detail

Product Tags

Our firm promises all consumers with the first-class products as well as most satisfying post-sale services. We warmly welcome our regular and new consumers to join us for Thermostatic Radiator Valve , Wax Actuator Suppliers , Thermostat For Water Cooler , Our intention should be to assist customers comprehend their goals. We have been creating terrific endeavours to obtain this win-win circumstance and sincerely welcome you to definitely join us!
Factory best selling TU-026D thermostatic cartridge wax sensor for sanitary ware to Denver Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory best selling
 TU-026D thermostatic cartridge wax sensor for sanitary ware  to Denver Importers detail pictures


Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for Factory best selling TU-026D thermostatic cartridge wax sensor for sanitary ware to Denver Importers, The product will supply to all over the world, such as: Puerto Rico , Lebanon , Miami , Selling our products causes no risks and brings high returns to your company instead. It is our consistent pursuit to create value for clients. Our company is looking for agents sincerely. What are you waiting for? Come and join us. Now or never.



  • Learn how this thermostatic recirculation valve eliminates hot water delivery issues while saving energy and extending the life of your domestic hot water supply …



    FUNCTION:
    when the ambient temperature exceeds the setpoint temp. , the LED is turned off and the relay cut-off the voltage and switches it to the fan/buzzer (optionally)…
    after a certain cooling time of sensor , the LED is turned on again (below setpoint temp.), the fan stops.

    DATASHEET:
    • RESISTOR R1, R2 : 1K
    • R3, R4 : 10K
    • R5 : 120K
    • R6 : 56K
    • R7 : 6M8
    • CAPACITOR C1, C2 : 100nF
    • DIODE D1, D2 : 1N4148
    • ZENER DIODE ZD1 : 5V1
    • IC SOCKET IC1
    • TRANSISTOR T1 : BC547
    • SCREW CONNECTOR
    • ELECTROLYTIC CAPACITOR C3 : 100µF
    • C4 : 470µF
    • RELAY RY1 : VR15M121C
    • TRIMMER RV1 : 100K
    • LED LD1
    • SENSOR NTC10K0 (Trigger: 5 to 30 degree celsius approx.)
    • IC IC1 : : LM324 or eq.
    • FAN dc 12V/0.16A
    • ADAPTOR ac/dc input: ac100-240V/output: dc12V

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane