Factory directly provide Thermostatic Wax Series for Philippines Factory
Short Description:
Product Detail
Product Tags
Factory directly provide Thermostatic Wax Series for Philippines Factory Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
|
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
|
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
||
|
B100 |
Powder, Slice , Column |
90/100 |
≥10 |
Non. |
Non. |
|
B105 |
Powder, Slice , Column |
95/105 |
≥10 |
Non. |
Non. |
|
B110 |
Powder, Slice , Column |
100/110 |
≥10 |
Non. |
Non. |
|
B115 |
Powder, Slice , Column |
105/115 |
≥10 |
Non. |
Non. |
|
B120 |
Powder, Slice , Column |
110/120 |
≥10 |
Non. |
Non. |
|
B125 |
Powder, Slice , Column |
115/125 |
≥10 |
Non. |
Non. |
|
B130 |
Powder, Slice , Column |
120/130 |
≥10 |
Non. |
Non. |
|
B135 |
Powder, Slice , Column |
125/135 |
≥10 |
Non. |
Non. |
|
B140 |
Powder, Slice , Column |
130/140 |
≥10 |
Non. |
Non. |
|
B145 |
Powder, Slice , Column |
135/145 |
≥10 |
Non. |
Non. |
|
B150 |
Powder, Slice , Column |
140/150 |
≥10 |
Non. |
Non. |
|
B155 |
Powder, Slice , Column |
145/155 |
≥10 |
Non. |
Non. |
|
B160 |
Powder, Slice , Column |
150/160 |
≥10 |
Non. |
Non. |
|
B165 |
Powder, Slice , Column |
155/165 |
≥10 |
Non. |
Non. |
|
B170 |
Powder, Slice , Column |
160/170 |
≥10 |
Non. |
Non. |
|
B175 |
Powder, Slice , Column |
165/175 |
≥10 |
Non. |
Non. |
|
B180 |
Powder, Slice , Column |
170/180 |
≥10 |
Non. |
Non |
Product detail pictures:

The organization keeps on the procedure concept "scientific management, high quality and efficiency primacy, purchaser supreme for Factory directly provide Thermostatic Wax Series for Philippines Factory, The product will supply to all over the world, such as: Ghana , Milan , Portugal , Certainly, competitive price, suitable package and timely delivery will be assured as per customers' demands. We sincerely hope to build business relationship with you on the basis of mutual benefit and profit in the very near future. Warmly welcome to contact us and become our direct cooperators.
How to retrieve and read the fault codes from a dual zone climate control system..Mercedes w208,….w203 is the same and w210 is similar..
THE CODES ARE LISTED BELOW
The # in brackets following the code is the location # of the faulty part..the following website shows the location for those parts.
https://w208.info/repair/electric
226 – In-car temperature sensor (B10/4)
227 – Outside temperature indicator temperature sensor (B14)
228 – Heater core temperature (B10/1)
229 – Heater core temperature (B10/1)
230 – Evaporator temperature sensor (B10/6)
231 – ECT sensor (B11/4)
232 – Refrigerant pressure sensor (B12)
233 – Refrigerant temperature sensor (B12/1)
234 – Sun sensor (B32)
235 – Emissions sensor (B31)
241 – Refrigerant fill
416 – Coolant circulation pump (M13)
417 – Duovalve (Y21y1), left
418 – Duovalve (Y21y2), right
419 – Electromagnetic clutch (A9k1)
420 – Idle speed increase
421 – Pulse module (N65)
422 – Series interface (K1) connection to instrument cluster (A1)
423 – Switchover valve block (Y11)
424 – Activated charcoal filter actuator (A32m2) open
425 – Activated charcoal filter actuator (A32m2) closed
432 – Non-USA DTC
459 – Series interface (K2) connection to instrument cluster (A1)
462 – Wide open throttle (WOT) position signal
stim141 is offline follow me on twitter https://twitter.com/fupabox
This is a video animation explains about the working of direction control valve and hydraulic ram or hydraulic cylinder with the help of a simple circuit, which is …






