Factory directly sale TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Muscat Factories Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

We will make every effort to be outstanding and perfect, and accelerate our steps for standing in the rank of international top-grade and high-tech enterprises for Factory directly sale TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Muscat Factories, The product will supply to all over the world, such as: Serbia , Cambodia , Seattle , As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality items we offer, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We are confident that we'll share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.
Double Acting:0°-90°
Output torque(0.5Mpa.Nm):16.6-2695
Operating Temperature:-20℃-+80℃
Connect apeopple’s thread:1/8
How to do a Relay Power Door Lock
Get the Book at Amazon:
https://www.createspace.com/3887599
Get the Android Book-APP:
https://play.google.com/store/apps/details?id=com.app.book.AOTSPDFJFVQCTYUQHR&feature=search_result#?t=W251bGwsMSwxLDEsImNvbS5hcHAuYm9vay5BT1RTUERGSkZWUUNUWVVRSFIiXQ..
Get the Kindle Book:
https://www.amazon.com/Automotive-Relay-Circuit-Guide-ebook/dp/B0085NBA4E/ref=sr_1_1?s=digital-text&ie=UTF8&qid=1358529593&sr=1-1&keywords=Automotive+Relay+Circuit+Guide
Power door locks have been around for many year, but manufacturers use different wiring schemes. One wiring scheme is resistive rest at ground, which has been used in the past by various manufacturers including Ford Motor Company. Resistive rest at ground is meant to keep both power door lock solenoids grounded, and then a positive pulse is applied when needed.
The power door solenoid or actuator is nothing more than a DC motor type component, which changes the direction of the lock actuation by reverse polarity. In other words, the door lock is actuated by reversing the polarity going to the solenoid. Here is where a relay becomes a very versatile controller of sorts.
Here’s how the circuit works:
Power is fed from the fuse to terminal 85 of the relay coil. This right away tells us that the relay actuation is going to be by ground, which is a lot safer. From the fuse, power is also fed to terminal 87 of the relay. This is a variation of how we normally connect terminal 30, which normally goes to power. But, not here where terminal 30 is used as an output. Terminal 87A is connected, on both relays, to chassis ground.
In this configuration, both relays connect the …. Get the whole story right here in this video…Enjoy…
Amazon Printed-Books & Kindle:
https://www.amazon.com/s/ref=nb_sb_noss_1?url=search-alias%3Dstripbooks&field-keywords=mandy+concepcion
Google Play Android APPs:
https://play.google.com/store/search?q=mandy+concepcion&c=apps
Amazon Video DVDs:
https://www.amazon.com/s/ref=nb_sb_noss_1?url=search-alias%3Dmovies-tv&field-keywords=mandy+concepcion
Barnes & Noble Nook:
https://www.barnesandnoble.com/s/mandy-concepcion?keyword=mandy+concepcion&store=allproducts
Apple iTunes iPad:
https://itunes.apple.com/us/artist/mandy-concepcion/id449573393?mt=11