factory Outlets for TU-1C01 thermal wax actuator for air conditioner and compressor for Ethiopia Manufacturers

factory Outlets for
 TU-1C01 thermal wax actuator for air conditioner and compressor for Ethiopia Manufacturers

Short Description:

Product Detail

Product Tags

We've been commitment to offer the competitive rate ,outstanding merchandise good quality, too as fast delivery for Air Compressor Accessories , Wholesale Sensing Wax , Exposed Thermostatic Shower Valve , On account of superior excellent and aggressive rate , we will be the sector leader, make sure you don’t hesitate to contact us by cellular phone or email, if you're fascinated in almost any of our items.
factory Outlets for TU-1C01 thermal wax actuator for air conditioner and compressor for Ethiopia Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

factory Outlets for
 TU-1C01 thermal wax actuator for air conditioner and compressor for Ethiopia Manufacturers detail pictures


We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for factory Outlets for TU-1C01 thermal wax actuator for air conditioner and compressor for Ethiopia Manufacturers, The product will supply to all over the world, such as: Monaco , Tajikistan , United Arab Emirates , Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound solutions with good logistics service and economical cost. Depending on this, our solutions are sold very well in the countries in Africa, the Mid-East and Southeast Asia.



  • Yes! by Finishing Touch is the instant, pain free hair remover with advanced sensa-light technology. With Finishing Touch Yes! you can say goodbye to painful or smelly hair removal methods. No more expensive or embarrassing waxing, laser, or electrolysis appointments. No more nicks and cuts. You can use Finishing Touch Yes! on your face, legs, bikini line and anywhere else you want to remove hair. It removes peach fuzz and facial hair, unwanted arm hair and help you achieve soft, smooth legs. Finishing Touch Yes! is even perfect for the man in your life and is great for all skin types and hair colors.

    Learn more at the official Yes! by Finishing Touch website at https://www.finishingtouchyes.com



    No heat or no A/C. Temperature control knob feels loose and is not controlling temperature control unit. Cable can come loose and needs to be reset on back of control panel. Honda Accord Civic Acura 1994 1995 1996 1997 heater air conditioning A/C is warm Freon valve air mixture freezing defrost blow smell knob easy fix Japanese Cars rice burner lx dx ex coupe wagon van repair manual Troubleshoot NO HEAT or A/C comes out Hot

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !