To regularly increase the management program by virtue from the rule of "sincerely, good religion and high quality are the base of enterprise development", we greatly absorb the essence of linked products internationally, and constantly produce new goods to satisfy the calls for of shoppers for Wax Valve Actuator , Thermal Actuator Valve , Electric Actuator Controller , Good quality is the key factor for the company to stand out from other competitors. Seeing is Believing, want more information? Just trial on its products!
factory Outlets for TU-1F91 thermal wax actuator for thermostatic automatic water drain valve Supply to Casablanca Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

factory Outlets for
 TU-1F91 thermal wax actuator for thermostatic automatic water drain valve Supply to Casablanca detail pictures


continue to improve, to ensure product quality in line with market and customer standard requirements. Our company has a quality assurance system have been established for factory Outlets for TU-1F91 thermal wax actuator for thermostatic automatic water drain valve Supply to Casablanca, The product will supply to all over the world, such as: Paraguay , Grenada , Mecca , We will do our utmost to cooperate & satisfied with you relying on top-grade quality and competitive price and best after service ,sincerely look forward to cooperating with you and make achievements in the future!



  • Replacing your Thermostat on Izusu Rodeo 1997­: The thermostat is a component of your cars cooling system. Its function is to regulate temperature and keep it at an ideal level.

    The thermostat is nothing more than a valve. Usually it is located at the top of the engine in the thermostat housing which is sometimes called the water outlet. If you follow the upper radiator hose back from the radiator to the engine, you’ll most likely find that the end of the hose is clamped to the thermostat housing. Inside the housing you will find the thermostat.

    The job of the thermostat is to control engine coolant temperature, thus regulating the engine’s operating temperature itself. The way this is accomplished is by the opening and closing of the thermostat. One side of the thermostat rests inside the intake manifold; it’s here that the thermostat reacts to the temperature of the engine coolant.

    When a car is first started the thermostat would be closed to prevent flow of coolant throughout the cooling system. This enables the engine to reach operating temperature more quickly because the coolant in the engine is heating up more rapidly due to its restriction by the thermostat. Once the engine reaches the desired operating temperature the thermostat opens and allows the coolant to flow throughout the cooling system. Once the fluid starts circulating it flows through the radiator where it is cooled down before returning to the engine block. This process prevents the engine from overheating.

    The opening and closing action of the thermostat is accomplished by the expansion or constriction of a spring that is part of the thermostat. Since the thermostat is surrounded by the engine coolant, the spring reacts to the coolant temperature causing the part to open or close.



    Motorized Slide Gate Damper – Actuator Operated Guillotine Dampers

    1. “CAIR” ON-OFF / MODULATING TYPE 415V AC THREE PHASE MULTI TURN ELECTRICAL ACTUATOR OPERATED SLIDE GATE DAMPER VALVE WITH INTREGAL STARTER UNIT CONTROLLER.

    ELECTRICAL ACTUATOR DETAILS:
    MANUFACTURER : CAIR EUROMATIC AUTOMATION PVT. LTD
    BRAND / MODEL : CAIR / ATM-IN
    CHARACTERISTIC : ON-OFF / MODULATING TYPE WITH INTEGRALSTARTER UNIT
    INPUT SIGNAL : 4~20mA
    FEEDBACK SIGNAL : 4~20mA(±5%)
    POWER SUPPLY : 415V AC (+/-10%)
    HOUSING & COVER : CAST IRON
    ENCLOSURE : WATER TIGHT IP 67
    AMBIENT TEMPERATURE : 20°C ~ 80°C
    TORQUE SWITCHES : 2 X SPDT
    LIMIT SWITCHES : 2 X SPDT
    STALL PROTECTION : BUILT IN THERMAL PROTECTION
    INDICATOR : CONTINUOUS POSITION INDICATOR
    MANUAL OVERRIDE : WHEEL TYPE

    INTEGRAL STARTER UNIT DETAILS:
     SELECTOR SWITCH : OPEN / STOP / CLOSE
     SELECTOR SWITCH : AUTO / MANUAL OR LOCAL/REMOTE
     INDICATING LAMPS : OPEN / CLOSE / ERROR
     ENCLOSURE : IP 67 WEATHER PROOF & DUST PROOF
     BLINKING LED LAMP INDICATION DURING OPEN/CLOSE OPERATION.
     | RED – FULLY OPEN | GREEN – FULLY CLOSED.
     AUTOMATIC PHASE ROTATION CORRECTION AND PHASE LOSS PROTECTION
     24V DC VOLTAGE LEVEL IS APPLIED FOR REMOTE CONTROL
     EASY AND FLEXIBLE USER CONNECTION WAY
     NON-PENETRATE LOCAL CONTROL SWITCH WITH HALL EFFECT DEVICE TO IMPROVE WATER PROOF FEATURE
     FIVE PASSIVE CONTACT TO INDICATE THE WORKING STATUS OF THE ELECTRIC ACTUATOR AND FACILITATING THE MONITORING OF THE ELECTRIC ACTUATOR BY DCS SYSTEM
     OPERATING MODE SELECT SWITCH CAN BE LOCKED WITH ORDINARY LOCK TO PREVENT IMPROPER OPERATION.

    SLIDE GATE VALVE DETAILS:
    BODY : IS 2062 Gr. B (M.S. FABRICATED)
    GATE : IS 2062 Gr. B (M.S. FABRICATED)
    SEAT : METAL TO METAL
    MAIN SHAFT : AISI 410
    LEACKAGE CLASS : IV
    TEMPERATURE :100°C to 500°C