High definition wholesale TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers Export to Kenya

High definition wholesale
 TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers Export to Kenya

Short Description:

Product Detail

Product Tags

No matter new buyer or old purchaser, We believe in long expression and trusted relationship for Motor Wax , Energe Wax Suppliers , Electric Linear Actuator 12v , Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
High definition wholesale TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers Export to Kenya Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

High definition wholesale
 TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers Export to Kenya detail pictures


We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for High definition wholesale TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers Export to Kenya, The product will supply to all over the world, such as: Malaysia , Mexico , Vancouver , we rely on own advantages to build a mutual-benefit commerce mechanism with our cooperative partners. As a result, now we have gained a global sales network reaching the Middle East, Turkey, Malaysia and Vietnamese.



  • Testing the 6″ oil expander im calling the hydrothermic actuator
    in this test we observe a start temp of 62 deg F and 9ml of fluid in the graduated cylinder and a final temp of 98 deg and 5.2 ml of expansion with 30 deg F of temp change. this amount of heat has produced 1000 psi inside the acuater



    There are several troubleshoots the furnace sticker lists that might be the problem. I point out several of them. If you dont care to learn anything about the furnace and what sets off an error code 33, then just skip to 6:00 to see the fix. But for most people I think it would be helpful to watch the whole thing, (sure would have saved me a ton of time.) But now I know a lot about furnaces!

    #33 LIMIT CIRCUIT FAULT – Indicates a limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts off. Flame Rollout switch and BVSS require manual reset. Check for:
    - Restricted Vent
    - Proper Vent Sizing
    - Loose blower wheel
    - Excessive wind
    - Dirty filter or restricted duct system
    - Defective blower motor or capacitor
    - Defective switch or connections
    - Inadequate combustion air supply (flame rollout switch open)

    Bryant Heating and Cooling Systems
    Natural Gas
    Central Furnace
    Model Number 310AAV048135 / 310AAV048135ACJA
    Manufactured JUL 2006
    1/2 HP Motor

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Key

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    WhatsApp Online Chat !