We take pleasure in an extremely fantastic standing among the our prospects for our great product top quality, competitive cost and the finest support for Diesel Engine Automatic Regulator , Wax Element Control Valve , Wax Type Temperature Control Valve , As we are moving forward, we keep an eye on our ever-expanding product range and make improvement to our services.
Hot Sale for TU-1H05 thermal wax actuator for thermostatic radiator valve for Russia Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Hot Sale for
 TU-1H05 thermal wax actuator for thermostatic radiator valve for Russia Factories detail pictures


We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Hot Sale for TU-1H05 thermal wax actuator for thermostatic radiator valve for Russia Factories, The product will supply to all over the world, such as: Italy , panama , Ecuador , Our company has already had a lot of top factories and professional technology teams in China, offering the best products, techniques and services to worldwide customers. Honesty is our principle, professional operation is our work, service is our goal, and customers' satisfaction is our future!



  • What is FAN COIL UNIT? What does FAN COIL UNIT mean? FAN COIL UNIT meaning – FAN COIL UNIT definition – FAN COIL UNIT explanation.

    Source: Wikipedia.org article, adapted under https://creativecommons.org/licenses/by-sa/3.0/ license.

    A Fan Coil Unit (FCU) is a simple device consisting of a heating and/or cooling heat exchanger or ‘coil’ and fan. It is part of an HVAC system found in residential, commercial, and industrial buildings. A fan coil unit is a diverse device sometimes using ductwork, and is used to control the temperature in the space where it is installed, or serve multiple spaces. It is controlled either by a manual on/off switch or by a thermostat, which controls the throughput of water to the heat exchanger using a control valve and/or the fan speed.

    Due to their simplicity and flexibility, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. Various unit configurations are available, including horizontal (ceiling mounted) or vertical (floor mounted).

    Noise output from FCUs, like any other form of air conditioning, is principally due to the design of the unit and the building materials around it. A correctly selected FCU, like some of those from the UK, can offer noise levels as low as NR25 or NC25

    The output from an FCU can be established by looking at the temperature of the air entering the unit and the temperature of the air leaving the unit, coupled with the volume of air being moved through the unit. This is a simplistic statement, and there is further reading on sensible heat ratios and the specific heat capacity of air, both of which have an effect on thermal performance..

    Firstly, it should be noted that ‘Fan Coil Unit’ is a generic term that is applied to a range of products. Also, the term ‘Fan Coil Unit’ will mean different things to users, specifiers, and installers in different countries and regions, particularly in relation to product size and output capability.

    Fan Coil Unit design falls principally into two main types: blow through and draw through. As the names suggest, in the first type the fans are fitted such that they blow through the heat exchanger, and in the other type the fans are fitted after the coil such that they draw air through it. Draw through units are considered thermally superior, as ordinarily they make better use of the heat exchanger. However they are more expensive, as they require a chassis to hold the fans whereas a blow-through unit typically consists of a set of fans bolted straight to a coil.

    A fan coil unit may be concealed or exposed within the room or area that it serves.

    An exposed fan coil unit may be wall-mounted, freestanding or ceiling mounted, and will typically include an appropriate enclosure to protect and conceal the fan coil unit itself, with return air grille and supply air diffuser set into that enclosure to distribute the air.

    A concealed fan coil unit will typically be installed within an accessible ceiling void or services zone. The return air grille and supply air diffuser, typically set flush into the ceiling, will be ducted to and from the fan coil unit and thus allows a great degree of flexibility for locating the grilles to suit the ceiling layout and/or the partition layout within a space. It is quite common for the return air not to be ducted and to use the ceiling void as a return air plenum.

    The coil receives hot or cold water from a central plant, and removes heat from or adds heat to the air through heat transfer. Traditionally fan coil units can contain their own internal thermostat, or can be wired to operate with a remote thermostat. However, and as is common in most modern buildings with a Building Energy Management System (BEMS), the control of the fan coil unit will be by a local digital controller or outstation (along with associated room temperature sensor and control valve actuators) linked to the BEMS via a communication network, and therefore adjustable and controllable from a central point, such as a supervisors head end computer.



    This video shows how a pH sensor and temperature sensor can be used in conjunction to monitor the pH levels and temperature of a pool. Once the readings for both sensors have been collected, the pH level and temperature are displayed on an LCD screen.

    Given a target pH level, the program will calculate the amount of chemicals needed to either increase or decrease the pH of the pool. Depending on the pools actual dimensions, the calculation to get the appropriate amount of added chemicals to alter pH levels can be adjusted.

    Here is a list of parts used:

    1. BNC pH Lab Electrode: RB-Phi-145 by Phidgets

    2. Practical Maker BNC Sensor Shield (sits on top of Arduino)