Low MOQ for TU-3A01 thermal wax actuator for air conditioner and compressor Supply to Qatar

Low MOQ for
 TU-3A01 thermal wax actuator for air conditioner and compressor Supply to Qatar

Short Description:

Product Detail

Product Tags

The key to our success is "Good Product Quality, Reasonable Value and Efficient Service" for Electric Actuator Limit Switch , Automotive Thermostat Housing , Thermal Actuator Uses , We are willing to give you the best suggestions on the designs of your orders in a professional way if you need. In the meantime, we keep on developing new technologies and creating new designs so as to make you ahead in the line of this business.
Low MOQ for TU-3A01 thermal wax actuator for air conditioner and compressor Supply to Qatar Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Low MOQ for
 TU-3A01 thermal wax actuator for air conditioner and compressor Supply to Qatar detail pictures


The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Low MOQ for TU-3A01 thermal wax actuator for air conditioner and compressor Supply to Qatar, The product will supply to all over the world, such as: Pakistan , Uruguay , Japan , As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products we offer, effective and satisfying consultation service is supplied by our specialist after-sale service group. Solution lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we are going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.



  • Fail-safe actuators are often used on crucial damper and valve applications that require protection from excessive temperatures. Back in the days when pneumatics ruled commercial HVAC controls, fail-safe protection was easy because pneumatic actuators are inherently fail-safe. When electric actuators began replacing pneumatics, however, things got more complicated. Capacitor-driven actuators now have many advantages over older spring-return electric actuators…



    How to clean the throttle body on a 4 cylinder 2AZ-FE Toyota.

    The intake must be removed to access the throttle body at the back of the engine bay.

    First, the air box and vacuum lines are removed, exposing the air filter. The air intake tube is then removed by loosening hose clamps around the throttle body.

    With the ignition in ON, floor the pedal to open the butterfly valve, since this vehicle is drive by wire. Use a toothbrush and throttle body cleaner to clean the carbon deposits in the throttle body. Clean excess cleaner with a rag and replace all components.

    The first start on the car will be hard and may require throttle input to burn the cleaner in the intake. If a check engine light illuminates, disconnect the battery for a few minutes to clear the code.

    Procedure was shown on a 2003 Toyota Camry 4 cylinder. Same procedure applies to 4 cylinder Rav4, Scion tC, Highlander, Solara and XRS Corolla and Matrix with the 2.4L engine.

    Perform a throttle body or idle air control valve cleaning if your car idles and runs rough, won’t start, has reduced throttle response or is getting bad fuel economy. Its also a good time to clean out the MAF (mass airflow sensor), PCV valve and change the air filter if it is dirty.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Key

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !
    Close