Low price for TU-1D05 thermal wax actuator for industrial thermostatic water regulations mixing valve to Rotterdam Manufacturers

Low price for
 TU-1D05 thermal wax actuator for industrial thermostatic water regulations mixing valve to Rotterdam Manufacturers

Short Description:

Product Detail

Product Tags

With our leading technology also as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future jointly with your esteemed company for Proportional Thermal Actuator , Thermal Or Magnetic Actuator , Parts For Air Conditioner , We believe that a passionate, innovative and well-trained team will be able to establish good and mutually beneficial business relationships with you soon. Please feel free to contact us for more details.
Low price for TU-1D05 thermal wax actuator for industrial thermostatic water regulations mixing valve to Rotterdam Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Low price for
 TU-1D05 thermal wax actuator for industrial thermostatic water regulations mixing valve to Rotterdam Manufacturers detail pictures


Persisting in "High quality, Prompt Delivery, Aggressive Price", we have established long-term cooperation with clientele from both equally overseas and domestically and get new and old clients' higher comments for Low price for TU-1D05 thermal wax actuator for industrial thermostatic water regulations mixing valve to Rotterdam Manufacturers, The product will supply to all over the world, such as: Amsterdam , Las Vegas , panama , Besides there are also professional production and management , advanced production equipment to assure our quality and delivery time , our company pursues the principle of good faith, high-quality and high-efficiency. We guarantee that our company will try our best to reduce customer purchase cost, shorten the period of purchase, stable products quality, increase customers' satisfaction and achieve win-win situation .



  • Code
    #include 16f877a.h
    #device adc=10 // Set ADC resolution to 10Bit
    #fuses XT,NOLVP,NOWDT,NOPROTECT
    #use delay(clock=4000000)
    #use rs232(baud=9600,xmit=PIN_C6,rcv=PIN_C7,ERRORS)
    #include “flex_lcd.c”

    #define LOAD PIN_B7
    #define THRES 30.0 // load switching threshold in Celsius

    int16 digital_reading; // ADC resolution is 10Bit, an 8Bit integer is not enough to hold the reading
    float temp;

    void main()

    /* ADC Initialization */
    setup_adc(ADC_CLOCK_INTERNAL); // initialize ADC with a sampling rate of Crystal/4 MHz
    setup_adc_ports(RA0_ANALOG); // set PIN_A0 as analog input channel
    set_adc_channel(0); // point ADC to channel 0 for ADC reading
    delay_ms(1); // ADC module is slow, needs some time to adjust.

    /* Peripherals Configurations */
    lcd_init(); // Turn LCD ON, along with other initialization commands
    output_low(LOAD); // the load is initially OFF
    lcd_gotoxy(1,1); // point LCD cursor to col1 row1
    lcd_putc(“Temperature is:”); // print on LCD

    while(1) // infinite loop

    digital_reading = read_adc(); // capture current temperature reading
    delay_us(100); // 0.1ms delay for ADC stabilization
    temp = digital_reading * 0.4883; // convert reading to Celsius
    lcd_gotoxy(1,2); // point LCD cursor to col1 row2
    printf(lcd_putc,”%2.1f C”,temp); // print value on LCD

    if(temp=THRES) output_high(LOAD); // Control Load
    else output_low(LOAD);

    delay_ms(1000); // 1 second delay between readings



    Wax Block HSMWorks Lab Assignment Demo
    Tools used:
    #51 Height Probe
    #52 1/2″ Endmill 4 flute Carbide
    #53 1/4″ 118 degree spot drill
    #54 #7 118 degree machine drill (stubby)
    #55 3/8″ Endmill 3 flute Carbide
    #56 1/2″ 90 degree spot drill

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !