We always think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and the living for Thermostatic Element , Automatic Hot Water Temperature Control Valves , Automatic Temperature Control System , Living by quality, development by credit is our eternal pursuit, We firmly believe that after your visit we will become long-term partners.
Manufactur standard TU-1C07 thermal wax actuator for air conditioner and compressor to Thailand Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

Manufactur standard
 TU-1C07 thermal wax actuator for air conditioner and compressor to Thailand Factories detail pictures


Persisting in "High quality, Prompt Delivery, Competitive Price", we have established long-term cooperation with clients from both overseas and domestically and get new and old clients' high comments for Manufactur standard TU-1C07 thermal wax actuator for air conditioner and compressor to Thailand Factories, The product will supply to all over the world, such as: Latvia , Panama , Sao Paulo , We rely on high-quality materials, perfect design, excellent customer service and the competitive price to win the trust of many customers at home and abroad. 95%products are exported to overseas markets.



  • How to test a car/truck thermostat to see if it is opening properly and not stuck.
    It the same principle no matter what car or engine you have.

    - – - – - – - – - – - -

    Due to factors beyond the control of FixItSam, it cannot guarantee against unauthorized modifications of this information, or improper use of this information. FixItSam assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. FixItSam recommends safe practices when working with power tools, automotive lifts, lifting tools, jack stands, electrical equipment, blunt instruments, chemicals, lubricants, or any other tools or equipment seen or implied in this video. Due to factors beyond the control of FixItSam, no information contained in this video shall create any express or implied warranty or guarantee of any particular result. Any injury, damage or loss that may result from improper use of these tools, equipment, or the information contained in this video is the sole responsibility of the user and not youtube.com/fixitsam.



    In this video I am showing you how to make an electric ignitor / detonator also called igniter or blasting cap made from a chrismas light and a 9volt battery.

    DICLAIMER:
    The video is made for educational purposes only and should not be made for any other intention then a safer way for lighting commercial legal fireworks from a distance.
    This will greatly decrease the amount of firework accident!

    Creativepyroscience

    ——-

    This experiment is meant for a safe way to light fireworks. You can detonate the firework from a safe distance with a switch if you attach electric wires on the + and – pole. And connect the detonator to the fuse of the firework.

    Make sure you buy the right christmas lights that are quite big and not the small version.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    WhatsApp Online Chat !
    Close