OEM Factory for TU-1C06 thermal wax actuator for thermostatic automatic water drain valve to Cologne Factories

OEM Factory for
 TU-1C06 thermal wax actuator for thermostatic automatic water drain valve to Cologne Factories

Short Description:

Product Detail

Product Tags

We generally continually give you quite possibly the most conscientious shopper company, and the widest variety of designs and styles with finest materials. These endeavours include the availability of customized designs with speed and dispatch for Traditional Radiator Valves , Thermal Actuator Valve , 10mm Radiator Valves , For further information, please do not hesitate to contact us. All inquiries from you will be highly appreciated.
OEM Factory for TU-1C06 thermal wax actuator for thermostatic automatic water drain valve to Cologne Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

OEM Factory for
 TU-1C06 thermal wax actuator for thermostatic automatic water drain valve to Cologne Factories detail pictures


We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for OEM Factory for TU-1C06 thermal wax actuator for thermostatic automatic water drain valve to Cologne Factories, The product will supply to all over the world, such as: Bahrain , Manila , Austria , Our monthly output is more than 5000pcs. We have set up a strict quality control system. Please feel free to contact us for further information. We hope that we can establish long-term business relationships with you and carry out business on a mutually beneficial basis. We are and will be always trying our best to serve you.



  • A quick video showing the single channel fan controller I made with an arduino. When I get the code simplified I will make this a 4-channel device and use it on my PC to control the fans for the liquid cooling loops.

    Credit on the circuit goes to Oscar Gonzalez @ bricogeek.com. He designed the circuit using a CNY75 optocoupler to isolate the Arduino from the 12V that is needed to run the fan. From there, I used a 2SC1384 transistor to amplify the PWM signal from the optocoupler. My fan doesn’t like PWM output and makes a high-pitched whining noise, so I used a 220uF capacitor across the motor leads to flatten the PWM output. Not a great solution, but it will work until I can find something better.

    Temp sensing comes from an LM35, however since I mostly deal in Fahrenheit, an LM34 would have worked better and eliminated some code for conversion. Trip points are set at 75 for fan shutoff, 85 for fan startup, and 90 for maximum. Once the temp has reached 85, it is dynamically adjusted from 15% – 100% between 75 and 90. Once it drops below 75 it shuts down.

    Revision:

    I have modified the circuit a bit to drive a larger load using a MOSFET instead of the 2SC1384 NPN Transistor. By increasing the PWM frequency of the ATmega’s timer1 frequency to 31.25kHz the fan whine has been eliminated.

    Source code can be found here:

    http://pastebin.com/ZRbuetwM



    The Power System Plus 2.6 Gallon Tank Air Compressor is a lightweight, portable and maintenance-free direct drive pump. It gives you .45 CFM at 90 PSI and .9 CFM at 40 PSI. The compressor is equipped with a drain petcock and rubber suction feet for stability.

    The Power System Plus 1/3HP 2.6-Gallon Tank Air Compressor is available at your neighborhood Pep Boys Auto Store today and shop online at http://www.pepboys.com/product/details/9232729.

    Follow The Boys on:
    Facebook: http://www.facebook.com/pepboysauto
    Twitter: http://twitter.com/pepboysauto
    Google+: http://bit.ly/PepGooglePlus

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    WhatsApp Online Chat !