OEM/ODM Factory for TU-1J02 thermal wax actuator for electric switch valve to Rotterdam Manufacturer

OEM/ODM Factory for
 TU-1J02 thermal wax actuator for electric switch valve to Rotterdam Manufacturer

Short Description:

Product Detail

Product Tags

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Automatic Temperature Control Faucet , Where To Buy Air Conditioner Parts , Thermal Valve Actuator , As a key enterprise of this industry, our company makes efforts to become a leading supplier, based on the faith of professional quality & worldwide service.
OEM/ODM Factory for TU-1J02 thermal wax actuator for electric switch valve to Rotterdam Manufacturer Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

OEM/ODM Factory for
 TU-1J02 thermal wax actuator for electric switch valve to Rotterdam Manufacturer detail pictures


Persisting in "High high quality, Prompt Delivery, Aggressive Price", we've established long-term cooperation with clients from the two overseas and domestically and get new and old clients' superior comments for OEM/ODM Factory for TU-1J02 thermal wax actuator for electric switch valve to Rotterdam Manufacturer, The product will supply to all over the world, such as: Venezuela , Maldives , Romania , Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .



  • More information on Assured Automation’s K Series 120 Volt AC Electric Actuators can be found at: https://assuredautomation.com/K4_electric_actuators/index.php

    Assured Automation is a leading provider of automated valves and flow components for industrial process control applications. For over 20 years we have been providing state of the art automation to a diverse clientele ranging from small equipment manufacturers to the Fortune 500 Manufacturing, Chemical and Pharmaceutical Companies.

    Our product line consists of a complete offering of standardized automated valve assemblies with a variety of commonly used accessory items. In addition, we offer complete valve automation services where we supply special automated valve assemblies developed around your specified products or your particular applications. Full CAD capabilities are offered including AutoCAD, Solidworks or other commonly used design and drawing programs.

    Our Goal is to make the selection, estimating and delivery of high quality automated valves and flow components as quick and easy as possible.



    This is another easy DIY job and something you should consider doing yourself to make sure it gets done right! If your car is taking a long time (longer than 5 minutes) for the heater to blow warm inside the car, that is often a good sign that the engine’s coolant thermostat is worn out. Easy replacement and your engine will run healthier and your body will be happier. This video applies to C320, E320, ML320, CLK320, SLK320. It also indirectly applies to most V/8 engines M113 of that period as well.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !