OEM/ODM Manufacturer TU-025 thermostatic cartridge wax sensor for sanitary ware for Pakistan Factory
Short Description:
Product Detail
Product Tags
OEM/ODM Manufacturer TU-025 thermostatic cartridge wax sensor for sanitary ware for Pakistan Factory Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for OEM/ODM Manufacturer TU-025 thermostatic cartridge wax sensor for sanitary ware for Pakistan Factory, The product will supply to all over the world, such as: New Delhi , Hamburg , Mauritania , We have won a good reputation among overseas and domestic clients. Adhering to the management tenet of "credit oriented, customer first, high efficiency and mature services", we warmly welcome friends from all walks of life to cooperate with us.
Motorized Slide Gate Damper – Actuator Operated Guillotine Dampers
1. “CAIR” ON-OFF / MODULATING TYPE 415V AC THREE PHASE MULTI TURN ELECTRICAL ACTUATOR OPERATED SLIDE GATE DAMPER VALVE WITH INTREGAL STARTER UNIT CONTROLLER.
ELECTRICAL ACTUATOR DETAILS:
MANUFACTURER : CAIR EUROMATIC AUTOMATION PVT. LTD
BRAND / MODEL : CAIR / ATM-IN
CHARACTERISTIC : ON-OFF / MODULATING TYPE WITH INTEGRALSTARTER UNIT
INPUT SIGNAL : 4~20mA
FEEDBACK SIGNAL : 4~20mA(±5%)
POWER SUPPLY : 415V AC (+/-10%)
HOUSING & COVER : CAST IRON
ENCLOSURE : WATER TIGHT IP 67
AMBIENT TEMPERATURE : 20°C ~ 80°C
TORQUE SWITCHES : 2 X SPDT
LIMIT SWITCHES : 2 X SPDT
STALL PROTECTION : BUILT IN THERMAL PROTECTION
INDICATOR : CONTINUOUS POSITION INDICATOR
MANUAL OVERRIDE : WHEEL TYPE
INTEGRAL STARTER UNIT DETAILS:
SELECTOR SWITCH : OPEN / STOP / CLOSE
SELECTOR SWITCH : AUTO / MANUAL OR LOCAL/REMOTE
INDICATING LAMPS : OPEN / CLOSE / ERROR
ENCLOSURE : IP 67 WEATHER PROOF & DUST PROOF
BLINKING LED LAMP INDICATION DURING OPEN/CLOSE OPERATION.
| RED – FULLY OPEN | GREEN – FULLY CLOSED.
AUTOMATIC PHASE ROTATION CORRECTION AND PHASE LOSS PROTECTION
24V DC VOLTAGE LEVEL IS APPLIED FOR REMOTE CONTROL
EASY AND FLEXIBLE USER CONNECTION WAY
NON-PENETRATE LOCAL CONTROL SWITCH WITH HALL EFFECT DEVICE TO IMPROVE WATER PROOF FEATURE
FIVE PASSIVE CONTACT TO INDICATE THE WORKING STATUS OF THE ELECTRIC ACTUATOR AND FACILITATING THE MONITORING OF THE ELECTRIC ACTUATOR BY DCS SYSTEM
OPERATING MODE SELECT SWITCH CAN BE LOCKED WITH ORDINARY LOCK TO PREVENT IMPROPER OPERATION.
SLIDE GATE VALVE DETAILS:
BODY : IS 2062 Gr. B (M.S. FABRICATED)
GATE : IS 2062 Gr. B (M.S. FABRICATED)
SEAT : METAL TO METAL
MAIN SHAFT : AISI 410
LEACKAGE CLASS : IV
TEMPERATURE :100°C to 500°C
This is a fastener-by-fastener description of how I diagnosed and repaired a slow coolant leak as a result of a bad coolant hose flange on a 2001 VW MKIV Jetta Sedan with automatic trans and 2.0L (AEG) engine. This is a known issue with VW engines including the MKIV, and it is the most common cause of a slow coolant leak for this vintage engine.
Note that the coolant used in many VW engines is G12, only available through the dealer. Literature published by VW explains that G12 is not compatible with other coolants, including universal coolant sold elsewhere. They warn that mixing G12 with other coolants might cause engine or seal or sensor damage, and that their warranty may be void if there is evidence of coolant mixing and damage resulting from that.
There is another useful description of how this repair is done at the following link done by MikeWire on the VW Vortex forum.
https://forums.vwvortex.com/showthread.php?2970825-DIY-Replacing-driver-side-coolant-flange-on-a-MKIV-Jetta-8v-2.o%E2%80%A6
This video is posted for entertainment purposes, and is not an instructional guide. Do not attempt this at home without professional advice. I am not a professional mechanic, and any misadventure resulting from your attempt to repair your vehicle is your responsibility.