OEM/ODM Supplier for TU-1F05 thermal wax actuator for air conditioner and compressor Export to Qatar

OEM/ODM Supplier for
 TU-1F05 thermal wax actuator for air conditioner and compressor  Export to Qatar

Short Description:

Product Detail

Product Tags

We have a professional, efficiency team to provide quality service for our customer. We always follow the tenet of customer-oriented, details-focused for Thermal Actuator Design , Coleman Air Compressor , Automatic Temperature Control Of Room , Our tenet is evident all of the time: to deliver high quality solution at competitive price tag to clients throughout the planet. We welcome potential customers to get in touch with us for OEM and ODM orders.
OEM/ODM Supplier for TU-1F05 thermal wax actuator for air conditioner and compressor Export to Qatar Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

OEM/ODM Supplier for
 TU-1F05 thermal wax actuator for air conditioner and compressor  Export to Qatar detail pictures


With our loaded encounter and considerate services, we have now been recognized as a trustworthy supplier for lots of worldwide consumers for OEM/ODM Supplier for TU-1F05 thermal wax actuator for air conditioner and compressor Export to Qatar, The product will supply to all over the world, such as: Madagascar , Tajikistan , Mexico , We are your reliable partner in the international markets of our products. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade products in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market. We are willing to cooperate with business friends from at home and abroad, to create a great future. Welcome to Visit our factory. Looking forward to have win-win cooperation with you.



  • See how you can quickly test if your shower thermostat is working or not. Shop thermostatic cartridges on our website: https://bit.ly/1CcLQPx

    =====

    Questions about your shower? Contact us: https://bit.ly/write2showerdoc

    Join our weekly “24 Hour Special” mailing list: https://eepurl.com/fDlG2

    Visit The Shower Doctor at: https://www.showerdoc.com

    And also…
    Facebook: https://on.fb.me/V11Xct
    Twitter: https://bit.ly/Z5GC4D
    Pinterest: https://bit.ly/Vyx1Dr
    Foursquare: https://4sq.com/1zKUGjY
    The Shower Doctor blog: https://www.showerdoc.com/blog



    1. The alarm of cut-off function
    Detector and actuator is connected by wireless. If gas leakage reaches a dangerous concentration, the detector will alarm and signal. Then the controller will receive the signal and instruct the actuator to close the air valve.

    2.Over-flow Cut-off Function: It will closed automatically and cut off the gas source when the atmogenic switch,pressure regulator, gas stove loses control or the rubber hose ruptures, broken by biting of the mouse, breaks off that causes surpassing the current capacity.

    3.Over-pressure Protection Function: When the pressure regulator is out of work that causes the barometric pressure elevated suddenly and surpassed the security pressure, the safety valve automatically will cut off the source。

    4.The thermal cut-off function:
    When other accidental fires outbreak in the kitchen and the indoor temperature rises to more than 55 ℃, this valve can protect and cut off the gas source automatically. This valve doesn’t use plastic seals so that it can prevent gas leakage at a high temperature of 500 ℃.

    5.Energy Conversation and Discharge Reducing Function:actuator with an induction zone of magnetic field,magnetic field lines as link,recovery switch gravitational field as a straight line. When the gas through two different magnetic area,gas molecular group become atomization and enhances the heat efficiency, therebyreach the aimto save energy and reduce the harmful smog, in order to protect human health.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    WhatsApp Online Chat !