Original Factory TU-010 thermostatic cartridge wax sensor for sanitary ware Supply to Czech republic

Original Factory
 TU-010 thermostatic cartridge wax sensor for sanitary ware  Supply to Czech republic

Short Description:

Product Detail

Product Tags

We thinks what customers think, the urgency of urgency to act in the interests of a customer position of principle, allowing for better quality, lower processing costs, prices are more reasonable, won the new and old customers the support and affirmation for Ventilating Control , Automatic Temperature Control Valve , Where To Buy Expansion Wax, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Original Factory TU-010 thermostatic cartridge wax sensor for sanitary ware Supply to Czech republic Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Original Factory
 TU-010 thermostatic cartridge wax sensor for sanitary ware  Supply to Czech republic detail pictures


"Quality 1st, Honesty as base, Sincere company and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for Original Factory TU-010 thermostatic cartridge wax sensor for sanitary ware Supply to Czech republic, The product will supply to all over the world, such as: Zambia , Lithuania , Finland , Our products are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!



  • The A/C compressor stopped working, and this is the pressure release valve blowing off the excess pressure. This costed me $1500 to replace. This is the 3rd A/C compressor in my 2007 Honda Odyssey.



    There are several troubleshoots the furnace sticker lists that might be the problem. I point out several of them. If you dont care to learn anything about the furnace and what sets off an error code 33, then just skip to 6:00 to see the fix. But for most people I think it would be helpful to watch the whole thing, (sure would have saved me a ton of time.) But now I know a lot about furnaces!

    #33 LIMIT CIRCUIT FAULT – Indicates a limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts off. Flame Rollout switch and BVSS require manual reset. Check for:
    - Restricted Vent
    - Proper Vent Sizing
    - Loose blower wheel
    - Excessive wind
    - Dirty filter or restricted duct system
    - Defective blower motor or capacitor
    - Defective switch or connections
    - Inadequate combustion air supply (flame rollout switch open)

    Bryant Heating and Cooling Systems
    Natural Gas
    Central Furnace
    Model Number 310AAV048135 / 310AAV048135ACJA
    Manufactured JUL 2006
    1/2 HP Motor

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Key

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !