Automatic Temperature Regulating Agent Series is a kind of thermal expansion materials, which depends on principles that the substance expands when it is heated and constricts when it is cooled and a liquid is incompressible. It can automatically regulate temperature. When the ambient temperature goes up to the special value, Automatic Temperature Regulating Agent goes up to the special temperature with the ambient temperature, its unit volume increases. When the ambient temperature falls down to special value, Automatic Temperature Regulating Agent also falls down to the special temperature with the ambient temperature, its unit volume reduces. The agent is loaded in the purpose-made thermostatic element. The variation of ambient temperature takes a pressure and the thermostatic element takes a change, and this change brings the movement of either the appurtenance of the thermodynamic component or itself, thereby carrying out the automatic opening & closing function. All sorts of temperature controllers and the electrical switches are developed depending on the physical feature of Automatic Temperature Regulating Agent. It has been widely used in the fields of refrigeration, auto-control system, automobile industry, petrochemical industry, sanitary ware, heating and ventilating, electric electron, building, space & aviation etc.
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
||
A45 |
Powder, Slice , Column |
45/55 |
7 |
Non. |
Non. |
A45-1 |
Powder, Slice , Column |
45/55 |
10 |
Non. |
Non. |
A45-2 |
Powder, Slice , Column |
45/60 |
11 |
Non. |
Non. |
A48 |
Powder, Slice , Column |
48/60 |
7 |
Non. |
Non. |
A50 |
Powder, Slice , Column |
50/60 |
8 |
Non. |
Non. |
A50-1 |
Powder, Slice , Column |
50/75 |
6 |
Non. |
Non. |
A51 |
Powder, Slice , Column |
51/60 |
10 |
Non. |
Non. |
A52 |
Powder, Slice , Column |
52/55 |
3 |
Non. |
Non. |
A53 |
Powder, Slice , Column |
53/59 |
7 |
Non. |
Non. |
A54 |
Powder, Slice , Column |
54/67 |
9 |
Non. |
Non. |
A55 |
Powder, Slice , Column |
55/62 |
7 |
Non. |
Non. |
A55-1 |
Powder, Slice , Column |
55/65 |
10 |
Non. |
Non. |
A55-2 |
Powder, Slice , Column |
55/70 |
11 |
Non. |
Non. |
A57 |
Powder, Slice , Column |
57/66 |
10 |
Non. |
Non. |
A58 |
Powder, Slice , Column |
58/70 |
8 |
Non. |
Non. |
A60 |
Powder, Slice , Column |
60/70 |
6 |
Non. |
Non. |
A60-1 |
Powder, Slice , Column |
60/70 |
10 |
Non. |
Non. |
A60-2 |
Powder, Slice , Column |
60/75 |
4 |
Non. |
Non. |
A60-3 |
Powder, Slice , Column |
60/75 |
11 |
Non. |
Non. |
A60-4 |
Powder, Slice , Column |
60/80 |
2 |
Non. |
Non. |
A60-5 |
Powder, Slice , Column |
60/85 |
10 |
Non. |
Non. |
A60-6 |
Powder, Slice , Column |
60/100 |
5 |
Non. |
Non. |
A63 |
Powder, Slice , Column |
63/75 |
8 |
Non. |
Non. |
Product detail pictures:
Bear "Customer 1st, Good quality first" in mind, we work closely with our prospects and supply them with efficient and professional services for Rapid Delivery for Medial Temperature Wax for United Kingdom Importers, The product will supply to all over the world, such as: Ukraine , Mauritania , Amsterdam , We have a dedicated and aggressive sales team, and many branches, catering to our main customers. We are looking for long-term business partnerships, and ensure our suppliers that they will definitely benefit in both short and long run.
Welcome to BK Actuators, Manufacturer and Supplier of Electrical Actuators, Actuated Valves and Fire Dampers. The company was established in 2002 at Mumbai. Sophisticated infrastructure facility and vast industry experience make us different from others. Client centric approach, large production capacity and Flexible payment modes make us the first choice of our clients. We offer a diverse range of Electrical Actuators, Fire Dampers and Stainless Steel Strainers. Electrical Actuators and Actuated Valves offered by us are acknowledged for their functionality. Our Industrial Ball and Diaphragm Valves are available at industry leading prices. We are one of the trusted names of the industry engaged in offering genuine quality Fire Dampers and Stainless Steel Strainers. We are engaged in offering supreme quality Pneumatic Cylinders and Actuator for Dampers that are setting a benchmark in the market. Along with that we offer Butterfly Valve for Exhausts and Non Return Valve for Air Compressors that are best in the industry amongst others. For More Information, Log On At https://www.bkactuators.com/
Automatic Climate Controls (if so equipped)
This is the climate control panel for adjusting air flow, fan speed, temperature, air conditioning, defrosting or defogging, and air intake.
The Auto mode may be used all year round. For automatic cooling or dehumidified heating, turn both the FAN SPEED CONTROL dial and the AIR FLOW CONTROL dial to AUTO. It will automatically regulate and maintain fan speed, air flow and temperature in the cabin.
This FAN SPEED CONTROL dial regulates fan speed at various settings. Turn to the left for slower speed, to the right for higher speed. To turn the system OFF, turn the dial all the way to the left.
Press the AC button to turn the air conditioning ON. An indicator light will illuminate. Press again to turn OFF. This is the TEMPERATURE CONTROL dial in the center. Turn it to the left for cooler, or to the right for warmer air.
This is the AIR FLOW CONTROL dial, which allows you to select air flow outlets. Refer to the pictograms for the various air flow combinations:
- Air will flow from center and side vents, From center, side and foot vents, Mainly from foot vents, and from the defroster and foot vents
Note: in hot or humid conditions, a visible mist may be seen coming from the vents. This does not indicate a malfunction.
Press THIS button to change the air circulation mode to air recirculation, outside air circulation or automatic control. When the air recirculation mode is selected, this indicator light will illuminate. The flowing air is recirculated inside the vehicle. This helps AC efficiency and helps block outside odors from entering the cabin. When the outside air circulation mode is selected, this indicator light will illuminate and fresh air will be drawn into the vehicle. If the circulation mode is set to automatic control, both indicator lights will turn OFF and the air intake will be controlled automatically.
To defrost or defog front and side windows, turn the AIR FLOW CONTROL dial to the DEFROST setting. Next, turn the TEMPERATURE CONTROL dial left or right to set the desired temperature. To set the defroster on high, turn the FAN SPEED dial all the way to the right. For windshield deicing, your temperature selector should be turned to maximum heat.
To defrost or defog the rear window and, if so equipped, the outside mirrors, push the REAR WINDOW DEFROSTER switch. The indicator light will illuminate. After defrosting, push to turn OFF. If not turned OFF manually, this feature will automatically deactivate in 15 minutes.