Top Quality TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Toronto Factories

Top Quality
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Toronto Factories

Short Description:

Product Detail

Product Tags

Our corporation insists all along the quality policy of "product top quality is base of organization survival; purchaser pleasure will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" plus the consistent purpose of "reputation very first, purchaser first" for Automatic Temperature Control Of Room , Thermostatic Faucet , Air Conditioner Part , Our Company Core Principle: The prestige first ;The quality guarantee ;The customer are supreme.
Top Quality TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Toronto Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Top Quality
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Toronto Factories detail pictures


We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Top Quality TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Toronto Factories, The product will supply to all over the world, such as: Benin , Kyrgyzstan , Rome , Since always, we adhering to the "open and fair, share to get, the pursuit of excellence, and creation of value"values, adhere to the"integrity and efficient, trade-oriented, best way , best valve" business philosophy. Together with our all over the world have branches and partners to develop new business areas, maximum common values. We sincerely welcome and together we share in global resources, opening up new career together with the chapter.



  • This video provides step-by-step instructions for replacing the defrost thermostat on Frigidaire refrigerators and freezers. The most common reasons for replacing the defrost thermostat are when the refrigerator’s freezer is cold but the fridge is warm, or when the fridge is not defrosting.

    Click here to purchase Part #5303918214: https://www.repairclinic.com/PartDetail/Defrost-Thermostat/5303918214/892545?TLSID=1873

    Additional fridge repair, troubleshooting tips, help with finding your model number, and part replacement videos: https://www.repairclinic.com/RepairHelp/Refrigerator-Repair-Help?TLSID=1873

    All the information in this defrost thermostat replacement video is applicable to the following brands: Frigidaire, Kenmore, Westinghouse, Gibson, Crosley, Electrolux.

    Tools used: nutdriver, screwdriver, wire cutter

    Connect With Us!

    https://plus.google.com/+repairclinic

    https://www.facebook.com/RepairClinic

    https://www.twitter.com/RepairClinic

    https://pinterest.com/RepairClinic/

    Join our free VIP email list for discounts and money-saving tips: https://tinyurl.com/pnnh3be
    Check out our blog: https://www.DIY.RepairClinic.com

    Don’t forget to like and comment on this video, and subscribe to our channel!



    HVAC actuator replacement on a 2004 GMC envoy SLT with Automatic climate control. After replacing the Blower control module this GMC envoy would only blow air out of the defrost vent, a telltale sign of a faulty Mode door actuator. I show you how to replace an HVAC actuator and Perform an HVAC module recalibration.

    Applies to all vehicles based on the GMT 360 platform which includes 02-09 Chevrolet Trailblazer,
    02-09 Gmc Envoy,
    02-04 Oldsmobile Bravada,
    03-07 Isuzu Ascender,
    04-07 Buick Rainier and
    05-09 Saab 9-7X

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !