15 Years Factory wholesale Thermostatic Wax Series for Chicago Manufacturers
Short Description:
Product Detail
Product Tags
15 Years Factory wholesale Thermostatic Wax Series for Chicago Manufacturers Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
|
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
|
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
||
|
B100 |
Powder, Slice , Column |
90/100 |
≥10 |
Non. |
Non. |
|
B105 |
Powder, Slice , Column |
95/105 |
≥10 |
Non. |
Non. |
|
B110 |
Powder, Slice , Column |
100/110 |
≥10 |
Non. |
Non. |
|
B115 |
Powder, Slice , Column |
105/115 |
≥10 |
Non. |
Non. |
|
B120 |
Powder, Slice , Column |
110/120 |
≥10 |
Non. |
Non. |
|
B125 |
Powder, Slice , Column |
115/125 |
≥10 |
Non. |
Non. |
|
B130 |
Powder, Slice , Column |
120/130 |
≥10 |
Non. |
Non. |
|
B135 |
Powder, Slice , Column |
125/135 |
≥10 |
Non. |
Non. |
|
B140 |
Powder, Slice , Column |
130/140 |
≥10 |
Non. |
Non. |
|
B145 |
Powder, Slice , Column |
135/145 |
≥10 |
Non. |
Non. |
|
B150 |
Powder, Slice , Column |
140/150 |
≥10 |
Non. |
Non. |
|
B155 |
Powder, Slice , Column |
145/155 |
≥10 |
Non. |
Non. |
|
B160 |
Powder, Slice , Column |
150/160 |
≥10 |
Non. |
Non. |
|
B165 |
Powder, Slice , Column |
155/165 |
≥10 |
Non. |
Non. |
|
B170 |
Powder, Slice , Column |
160/170 |
≥10 |
Non. |
Non. |
|
B175 |
Powder, Slice , Column |
165/175 |
≥10 |
Non. |
Non. |
|
B180 |
Powder, Slice , Column |
170/180 |
≥10 |
Non. |
Non |
Product detail pictures:

We attempt for excellence, company the customers", hopes to be the top cooperation team and dominator company for personnel, suppliers and customers, realizes price share and continual marketing for 15 Years Factory wholesale Thermostatic Wax Series for Chicago Manufacturers, The product will supply to all over the world, such as: Angola , South Africa , Nicaragua , Over the years, with high-quality products, first- class service, ultra-low prices we win thee trust and favor of customers. Nowadays our products sell all over the domestic and abroad. Thanks for the regular and new customers support. We provide high quality product and competitive price, welcome the regular and new customers cooperate with us!
In this video we show How to replace the oxygen (O2) sensor also known has Air Fuel Ratio sensor on the Nissan Frontier V6 (3300 – VG33E) engine.Here you will see the difference between Bank #1 (right side)and Bank #2(left side) heated (4-wire) oxygen sensors. Replacing the oxygen sensor every 60-70,000 miles is an effort to help conserve fuel/gasoline.The oxygen sensor are not the only device to harness against waste consumption. The coolant temperature sensor at the thermostat housing reports to the computer, the computer commands the cooling fans through the fuel/relay box. Some model will be equipped with dual cooling fans. One for normal operation is the 1st fan. The 2nd fan is for air condition operation and over-heating conditions. If the Tstat remain stuck “close” the two fan will operate and coolant will overflow in its reserve container. The Tstat ONLY control engine temperature. The fans operation and gauge help radiates any heat or over heating base on ambient air temperature and operator.
The oxygen sensor is a state EPA “enviromental term” all so known has a EGT – exhaust gas temperature sensor sends millivoltage(data) to the ecm – engine control module for fuel injector control and its flow rate(impedeance). The oxygen sensor key roll is to measure the combustion flame/temperature .the ideal temperature for anything above 75% throttle is .870mv – .900mv output at the exhaust gas temperature/oxygen sensor. The oxygen(o2) sensor also work in conjuction with the Mass Air Flow Meter/sensor for fuel injector control. So the oxygen sensor can also be conside a Air Fuel Ratio sensor and the Mass Air Flow meter is mounted on the intake manifold duct.
M18 sensors – Install finger tight then 1/2 – 3/4 turn with wrench/ O2 sensor socket.26-33ft. lbs
M12 sensors – Install finger tight then 3/4 – 1 turn with wrench / O2 sensor socket.13.2-17ft. lbs.
APPLICATION: 2003 NISSAN FRONTIER EX, Xterra
3300 CC ENGINE 4X4
PLEASE – RATE – COMMENT AND SUBSCRIBE.
* DO NOT drop or use an oxygen sensor that has been dropped as this may have caused shock damage to the ceramic cell.
* DO NOT use any compound on or around the sensor unless labeled as oxygen sensor friendly products.
* DO NOT use impact wrench or conventional socket type wrench to install sensor.
* DO NOT allow sensor or lead wire to touch exhaust manifold or any other hot component.
* DO NOT expose this product to water,oil,windshield cleaner, anti-corrosion oil,grease,terminal cleaner, etc.
* DO NOT use leaded fuels, silicone or metal based additives
* DO NOT store under high humidity conditions will promote rusting.
WARNING : Anti-seize compound may cause irritation to the skin or eyes. In case of contact, wash affected area with soap and water. In case of eye contact, Flush with water for 15 minutes. If irritation persists, consult a physician. If swallowed, DO NOT induce vomiting.
KEEP OUT OF REACH OF CHILDREN.
Rectangular optical windows CaF2, LiF, MgF sales@dmphotonics.com
CaF2 IR optical grade square plane parallel window – request a quote sales@dmphotonics.com
https://www.dmphotonics.com/12O017_CaF2%20square%20plane%20parallel%20window/CaF2%20IR%20optical%20grade%20square%20plane%20parallel%20window.htm
Sample specifications:
Type: square plane parallel window
Material: CaF2 IR optical grade
Dimensions: 12.5 x 12.5 mm (+0.0/-0.1 mm)
Thickness: 0.5 mm (+/-0.05 mm)
Surface quality: 40/20 scr/dig
Parallelism: ? 3 arc min
Clear aperture: ? 90% of total dimensions
Coating: none
CaF2 window IR grade and UV grade sales@dmphotonics.com
Online store – Always in stock! Best price guarantee!
CaF2 IR grade window, 12.5×12.5×0.5 mm
[W-CaF2-12.5-12.5-0.5]
https://greyhawkoptics.com/product_info.php?products_id=776&osCsid=1997599829e29ac134bca5ba20498dd2
Always in stock! Best price guarantee!
CaF2 window UV grade, o 25.4 mm x 3.0 mm
[W-CaF2-UV-25.4-3]
https://greyhawkoptics.com/product_info.php?products_id=750&osCsid=1997599829e29ac134bca5ba20498dd2
Always in stock! Best price guarantee!
CaF2 window IR grade, o 25.4 mm x 3.0 mm
[W-CaF2-IR-25.4-3]
https://greyhawkoptics.com/product_info.php?products_id=353&osCsid=1997599829e29ac134bca5ba20498dd2
Hemicylinders from CaF2, Fused Silica, ZnSe,
https://www.dmphotonics.com/Hemicylindrical_Prism/hemicylindrical%20prism.htm
Calcium Fluoride (CaF2) prisms
https://www.dmphotonics.com/Calcium-Fluoride/Calcium-Fluoride-CaF2-prism.htm
Dispersion prism, IR grade CaF2, 15x15x15x10 mm, 25x25x25x25mm – always in stock! – request a quote
Del Mar Photonics offers variety of optical components from VUV grade and IR grade Lithium Fluoride.
https://www.dmphotonics.com/LiF_Lithium-Fluoride_Optics/Lithium%20Fluoride%20Properties.htm
Lithium Fluoride (LiF) – request a quote sales@dmphotonics.com
Lithium Fluoride is used for windows, lenses and prisms in the vacuum UV, UV, visible and infrared where transmission in the range 0.15µm to 6µm is desired. The refractive index varies from about 1.4 to 1.3 in this range. These crystals are optically isotropic, middle hard, unsolubale in water. Modest precautions should be taken against moisture and high energy radiation damage. LiF is attacked by atmospheric moisture at 400° C, and softens at 600° C. LiF is sensitive to thermal shock. This is the best VUV transmitter available.
Lithium Fluoride is used for windows, lenses and prisms in the vacuum UV, UV, visible and infrared where transmission in the range 0.15m m to 6m m is desired. The refractive index varies from about 1.4 to 1.3 in this range. These crystals are optically isotropic, middle hard, unsolubale in water. Modest precautions should be taken against moisture and high energy radiation damage. LiF is attacked by atmospheric moisture at 400° C, and softens at 600° C. LiF is sensitive to thermal shock. This is the best VUV transmitter available.
https://www.sciner.com/Opticsland/LiF.htm
Type: square plane-parallel window Material: VUV grade LiF Orientation: 100 Dimensions: 20 x 20 mm (+0.0/-0.2 mm) Thickness: 3 mm (+0.0/-0.2 mm) Surface quality: 60/40 scr/dig Flatness: 5 fringes at 532 nm Parallelism: ? 5 arc minutes Clear aperture: ? 85% of dimensions Coating: none
Part number: VUV_LiF_20_20_3
https://www.dmphotonics.com/LiF_Lithium-Fluoride_Optics/square%20plane-parallel%20window%20Material%20VUV%20grade%20LiF%20Orientation%20100%20Dimensions%2020%20x%2020%20mm.htm
LiF optical windows (custom order)
https://www.dmphotonics.com/LiF_Lithium-Fluoride_Optics/square%20plane-parallel%20window%20Material%20VUV%20grade%20LiF%20Orientation%20100%20Dimensions%2020%20x%2020%20mm.htm
Material: LiF optical VUV grade
monocrystalline
Working wavelength: 532 nm
Type: circular wedge window
Orientation: 100
Diameter: 2 mm (+0.0/-0.2 mm)
Thickness: 5 mm (+/-0.25 mm)
Finish: 2 sides polished 40/20 scr/dig
Flatness: 5 fringes per inch at 532 nm
Wedge angle on one side 3 deg
(+/- 0.5 deg)
Chamfers: technological for protection from
edge cracks
Coating: none
Part number: LiF_WW_D2_5