It adheres to the tenet "Honest, industrious, enterprising, innovative" to develop new products constantly. It regards customers, success as its own success. Let us develop prosperous future hand in hand for Electric Cylinder Actuator , Thermal Analysis Of Actuator , Air Compressor Spare Parts , We welcome you to join us in this path of creating a prosperous and efficient business together.
2017 Latest Design TU-1C01 thermal wax actuator for air conditioner and compressor for Russia Manufacturer Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

2017 Latest Design 
 TU-1C01 thermal wax actuator for air conditioner and compressor for Russia Manufacturer detail pictures


With a sound business credit, excellent after-sales service and modern manufacturing facilities, we have earned an excellent reputation among our customers across the world for 2017 Latest Design TU-1C01 thermal wax actuator for air conditioner and compressor for Russia Manufacturer, The product will supply to all over the world, such as: French , Greece , Guinea , We have constructed strong and long co-operation relationship with an enormous quantity of companies within this business overseas. Immediate and specialist after-sale service supplied by our consultant group has happy our buyers. Detailed Info and parameters from the merchandise will probably be sent to you for any thorough acknowledge. Free samples may be delivered and company check out to our corporation. n Portugal for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.



  • Casting light-weight parts with PolyFoam R2 expanding polyurethane foam. For more information on Polytek® polyurethane foams: https://goo.gl/e1RV6j.

    https://www.polytek.com

    https://www.facebook.com/polytekdevelopmentcorp

    https://www.twitter.com/PolytekUSA



    Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster