Automatic Temperature Regulating Agent Series is a kind of thermal expansion materials, which depends on principles that the substance expands when it is heated and constricts when it is cooled and a liquid is incompressible. It can automatically regulate temperature. When the ambient temperature goes up to the special value, Automatic Temperature Regulating Agent goes up to the special temperature with the ambient temperature, its unit volume increases. When the ambient temperature falls down to special value, Automatic Temperature Regulating Agent also falls down to the special temperature with the ambient temperature, its unit volume reduces. The agent is loaded in the purpose-made thermostatic element. The variation of ambient temperature takes a pressure and the thermostatic element takes a change, and this change brings the movement of either the appurtenance of the thermodynamic component or itself, thereby carrying out the automatic opening & closing function. All sorts of temperature controllers and the electrical switches are developed depending on the physical feature of Automatic Temperature Regulating Agent. It has been widely used in the fields of refrigeration, auto-control system, automobile industry, petrochemical industry, sanitary ware, heating and ventilating, electric electron, building, space & aviation etc.
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
||
A45 |
Powder, Slice , Column |
45/55 |
7 |
Non. |
Non. |
A45-1 |
Powder, Slice , Column |
45/55 |
10 |
Non. |
Non. |
A45-2 |
Powder, Slice , Column |
45/60 |
11 |
Non. |
Non. |
A48 |
Powder, Slice , Column |
48/60 |
7 |
Non. |
Non. |
A50 |
Powder, Slice , Column |
50/60 |
8 |
Non. |
Non. |
A50-1 |
Powder, Slice , Column |
50/75 |
6 |
Non. |
Non. |
A51 |
Powder, Slice , Column |
51/60 |
10 |
Non. |
Non. |
A52 |
Powder, Slice , Column |
52/55 |
3 |
Non. |
Non. |
A53 |
Powder, Slice , Column |
53/59 |
7 |
Non. |
Non. |
A54 |
Powder, Slice , Column |
54/67 |
9 |
Non. |
Non. |
A55 |
Powder, Slice , Column |
55/62 |
7 |
Non. |
Non. |
A55-1 |
Powder, Slice , Column |
55/65 |
10 |
Non. |
Non. |
A55-2 |
Powder, Slice , Column |
55/70 |
11 |
Non. |
Non. |
A57 |
Powder, Slice , Column |
57/66 |
10 |
Non. |
Non. |
A58 |
Powder, Slice , Column |
58/70 |
8 |
Non. |
Non. |
A60 |
Powder, Slice , Column |
60/70 |
6 |
Non. |
Non. |
A60-1 |
Powder, Slice , Column |
60/70 |
10 |
Non. |
Non. |
A60-2 |
Powder, Slice , Column |
60/75 |
4 |
Non. |
Non. |
A60-3 |
Powder, Slice , Column |
60/75 |
11 |
Non. |
Non. |
A60-4 |
Powder, Slice , Column |
60/80 |
2 |
Non. |
Non. |
A60-5 |
Powder, Slice , Column |
60/85 |
10 |
Non. |
Non. |
A60-6 |
Powder, Slice , Column |
60/100 |
5 |
Non. |
Non. |
A63 |
Powder, Slice , Column |
63/75 |
8 |
Non. |
Non. |
Product detail pictures:
Assume full responsibility to meet all demands of our clients; achieve continuous advancements by promoting the growth of our clients; become the final permanent cooperative partner of clients and maximize the interests of clients for Best quality and factory Medial Temperature Wax for Ecuador Manufacturer, The product will supply to all over the world, such as: Uganda , Czech , Angola , During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
Electrical and Electronics Engineering Questions and Answers site: https://electronics2electrical.com
Electrical and Electronics Engineering community is place where you can ask questions and receive answers from other members of the community. feel free to ask any question from basic to advanced level related to college study or work. Ask any problem from book or any practical problem in project also you can ask about seminar. If you are engineering student doing B.E. or engineer then here you can solve your problems in group by asking questions publicly and help other members by answering their questions and problems. Do not forget to Invite your friends.
REGISTER NOW https://electronics2electrical.com
APP https://play.google.com/store/apps/details?id=electronicselectrical.com.electricalandelectronicseng
AFFILIATE LINK
https://amzn.to/2fHA1fA
A properly designed steam system is extremely important. Clean, dry steam through your steam distribution network maximizes the quality of steam, and protects all related components thus keeping costs and maintenance to a minimum.
Principles of Operation of the Pressure Reducing Valve: – Normal positions before start-up are with the main valve closed and the pilot valve held open by spring force or air pressure. Entering steam passes through the pilot valve into the main diaphragm chamber and also out through the control orifice. As flow through the pilot valve exceeds flow through the orifice, control pressure increases in the diaphragm chamber and opens the main valve. As steam flows through the main valve, the increase in downstream pressure feeds back through the pressure sensing line to the underside of the pressure diaphragm. When the force below that diaphragm balances the compression force of the spring above it, the pilot valve throttles. The control pressure maintained in the main diaphragm chamber positions the main valve to deliver just enough steam for the desired delivery pressure. Adjustment of the spring or air pressure above the pressure diaphragm changes the downstream pressure set point. When steam is no longer required, the sensing line pressure increases closing the pressure pilot and the control pressure bleeds back through the control orifice. This allows the main valve to hold the desired reduced pressure, and it may close tight for a dead-end shutoff.
Operation of the Spirax Sarco Model 25PRV Pressure Reducing Valve
0:0:24 No Flow Conditions
0:0:27 Steam Flow Begins
0:0:29 Progresses Toward Equilibrium
0:0:35 Attains Set Point
0:0:43 Increased Downstream Load
0:0:56 Elevated Setpoint
0:1:09 Downstream Shutoff
0:1:19 The Spirax Sarco Model 25PRV Features