Factory directly sale TU-1J04 thermal wax actuator for electric switch valve for Greece Factory

Factory directly sale
 TU-1J04 thermal wax actuator for electric switch valve for Greece Factory

Short Description:

Product Detail

Product Tags

Our commission is always to provide our customers and clientele with best quality and aggressive portable digital products for Automatic Temperature Control By Switching The Fan , Air Compressor Fittings , Automatic Temperature Control Of Fan , Our hugely specialized process eliminates the component failure and offers our consumers unvarying high quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
Factory directly sale TU-1J04 thermal wax actuator for electric switch valve for Greece Factory Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory directly sale
 TU-1J04 thermal wax actuator for electric switch valve for Greece Factory detail pictures


Adhering into the basic principle of "quality, assistance, effectiveness and growth", we have attained trusts and praises from domestic and worldwide client for Factory directly sale TU-1J04 thermal wax actuator for electric switch valve for Greece Factory, The product will supply to all over the world, such as: Greece , Chile , Suriname , With the development of the society and economy, our company will continue the "loyalty, dedication, efficiency, innovation" spirit of enterprise, and we will always adhere to the management idea of "would rather lose gold, do not lose customers heart". We will serve the domestic and foreign businessmen with sincere dedication, and let us create bright future together with you!



  • This model of a pressure reducing valve was produce for training purposes to help illustrate the main principles of how the valve works, Principal Design then animated the valve working with illustrated pressure within the cut away sections. From this model technical drawing were produced as well as a bill of materials and parts.

    In addition to the media work Principal Design also offered the facility to have the CAD model created turned into a physical model that the students would be able to interact with, and see the parts working and interaction with one another, dissemble and reassemble in a class room environment prior to working on the real valve in the field.

    With all CAD modeling at Principal Design we can pick up a project at any point in a project whether you’re at the initial napkin/envelop sketch stages, have technical drawings or halfway through the CAD modeling we can work with you.

    https://www.principaldesign.co.uk/Animations/CAD/cad_pressure_reducing_valve.html



    My 2013 Nissan Versa has had a heat shield come loose and rattle three different occasions. The first two were covered by warranty and both occurred during the first year of me owning it. My warranty was up during that first year, and it has held until about a month ago. The guy at the dealership told me it was between the engine and the transmission. I never worried about it, as it was under warranty at the time. However the heat shield that was doing the rattling was actually about the exhaust pipe on the passenger side of the car towards the rear. It takes a 10mm socket to tighten/loosen the bolts. The heat shield actually broke off from the part that the bolt attached to, so I just loosened the bolt and tucked that part under the second part of the heat shield. I’m sure it’ll come out again, but atleast this’ll stop that annoying rattle. I hope this video may help someone else who has had this problem. Thanks for watching!

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    WhatsApp Online Chat !