Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" and the theory of "quality the basic, trust the first and management the advanced" for Wax Element , Automobile Thermostat , Electric Actuator Manufacturer , We hope to establish more business relationships with customers all over the world.
Factory making TU-3A01 thermal wax actuator for electric switch valve to US Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory making
 TU-3A01 thermal wax actuator for electric switch valve to US Importers detail pictures


Reliable quality and good credit standing are our principles, which will help us at a top-ranking position. Adhering to the tenet of "quality first, customer supreme" for Factory making TU-3A01 thermal wax actuator for electric switch valve to US Importers, The product will supply to all over the world, such as: Paraguay , Nigeria , Malaysia , With the superior and exceptional service, we are well developed along with our customers. Expertise and know-how ensure that we are always enjoying the trust from our customers in our business activities. "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your service. Contact Us Today For further information, contact us now.



  • WENZHOU KANGTUO INTERNATIONAL TRADING – Exporter, Manufacturer, Supplier of Ball Valve, Pneumatic Actuator, Electric Valve, Electric Actuator, Industrial Pneumatic Valves from Wenzhou – 325000, Zhejiang, China

    Get more details visit here :-

    https://www.kangtuovalves.com/



    https://www.rpm-powered.com

    1. System error
    2. Actual value feeler virtually
    3. Actual value interior feeler console
    4. Actual value outside temperature – feeler wasserkasten
    5. Actual value outside temperature – feeler bumper
    6. Actual value blowing out feeler floor space
    7. Actual value blowing out feeler man Anstroemer
    8. Display check
    9. Actual digital value acknowledging potentiometer temperature flap
    10. Target digital value temperature flap
    11. Actual digital value acknowledging potentiometer A/C flap
    12. Target digital value A/C flap
    13. Actual digital value acknowledging potentiometer Fuss/Def flap
    14. Target digital value Fuss/Def flap
    15. Actual digital value acknowledging potentiometer ram air flap
    16. Target digital value ram air flap
    17. Driving speed (km/h) ( used on movie )
    18. Actual value of the blower tension (volt)
    19. Desired value of the blower tension (volt)
    20. Actual value of the compressor/on-board tension (volt)
    21. Number of low-voltage events
    (not volatilely)
    22. Switching status of the high pressure switch
    23. Number of high pressure events (volatile)
    24. Number of high pressure events (not volatile)
    25. A/D value kickdown switch
    26. A/D value hot light
    27. Engine speed
    28. Compressor number of revolutions
    29. Coding
    30. Software-Version
    31. Software index
    32. Potentiometer error counter temperature flap
    33. Potentiometer error counter A/C flap
    34. Potentiometer error counter Fuss/Def flap
    35. Potentiometer error counter ram air flap
    36. Temperature flap notice cold
    37. Temperature flap notice warm
    38. A/C flap notice closed
    39. A/C flap notice opened
    40. Fuss/Def flap notice Def
    41. Fuss/Def flap notice foot
    42. Ram air flap notice up
    43. Ram air flap notice too
    44. Operating cycle counter
    45. Interior temperature counted (Ninc) dig
    46. Outside temperature filtered (°C)
    47. Outside temperature not filtered (°C)
    48. ECOR
    49. Coolant temperature
    50. Service life in min
    51. Engine temperature °C
    52. Compressor switching off conditions
    53. Announcement more actively el. Exits:
    Compressor/circulating air valve/water valve
    54. Rule index
    55. Outside temperature °C
    56. Interior feeler virtually °C
    57. Interior feeler console °C
    58. Temperature wasserkasten °C
    59. Temperature bumper °C
    60. Blowing out feeler floor space °C
    61. Blowing out feeler man Anstroemer °C
    62. Sun intensity W/m-1
    63. Sun intensity filtered W/m-1
    64. Delta exhaust rise
    65. Delta A/C Klappenverschiebung
    66. Time constant/1.6 seconds
    67. Cold weather starting correction
    68. Maximum correcting variable for i and p-portion
    69. Actual value blowing out feeler foot (cnts)
    70. Desired value blowing out feeler foot (cnts)
    71. Deviation (Epsilon)
    72. Portion (+ heat/- cool)