Factory Outlets TU-1D02 thermal wax actuator for air conditioner and compressor to Niger Importers
Short Description:
Product Detail
Product Tags
Factory Outlets TU-1D02 thermal wax actuator for air conditioner and compressor to Niger Importers Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for Factory Outlets TU-1D02 thermal wax actuator for air conditioner and compressor to Niger Importers, The product will supply to all over the world, such as: Malta, Seychelles, Rio de Janeiro, Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market. welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
This shows the two vacuum pods that tend to fail most in post 9/85 Mercedes W126 vehicles. The two pods are for the air scoop that controls fresh/recirculated air. The problem manifests itself as center vents that mysteriously misbehave at odd times, usually when it is hottest outside.
The part numbers for the two pods are:
000 800 5775
000 800 5875
Also, while these came from a post 9/85 W126 vehicle, chances are the pods will have the same issue in the pre-9/85 cars. The major difference between these two revisions are the CCU and the vacuum solenoids which were individual prior to 9/85 and consolidated into one unit post 9/85. For all I know, the part numbers might even be the same…… I’m not sure. If anyone knows for sure please email me.






