Good quality 100% TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Gambia Importers

Good quality 100%
 TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Gambia Importers

Short Description:

Product Detail

Product Tags

Our enterprise since its inception, often regards solution excellent as enterprise life, continually strengthen output technology, enhance product high quality and continually strengthen organization total high-quality administration, in strict accordance using the national standard ISO 9001:2000 for Automatic Temperature Controller With Cooling System , Electronic Thermal Actuator With Wax Core , Thermostat Controller , We, with open arms, invite all interested potential buyers to visit our web-site or get in touch with us immediately for further information and facts.
Good quality 100% TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Gambia Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Good quality 100%
 TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Gambia Importers detail pictures


Our progress depends around the innovative machines, great talents and consistently strengthened technology forces for Good quality 100% TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Gambia Importers, The product will supply to all over the world, such as: Adelaide , Maldives , Kenya , Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We've been able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and items. For anyone who is interested in our company and products, be sure to make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are about to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please genuinely feel no cost to speak to us for enterprise. nd we believe we have been gonna share the most effective trading practical experience with all our merchants.



  • web:https://www.gmkvalve.com/
    Email : sales@gmkvalve.com / info@gmkvalve.com
    GMK VALVE was located in longwan town,wenzhou city of Zhejiang,where is the China Pump & Valve hometown.

    The main products of our company include ball valves, gate valves, globe valves, check valves, butterfly valves, plug valves,strainer valves, power station valves,and gas valves ect. Size from 1/2″ to 88″ (DN15 to DN2200);Pressure from 150Lb to 2500Lb (PN1.0Mpa to PN42.0Mpa); materials cover WCB, WCC, WC6, WC9, CF8, CF3, CF8m, CF3M, LCB, LCC, A105, 304, 316, 304L, 316L, F11, F22, LF2, F51,B148, ALLOY 20, UB6, Titanium, Hastelloy, Inconel,duplex stainless steel, Monel, Monel etc.

    The products are widely applied in petroleum, chemical industry, natural gas, electric power, metallurgy, pharmacy, pulp & paper, urban construction and long transportation pipeline projects. Our products are sold well worldwide include America, Europe, Southeast Asia, Middle East and Africa ect. Certificated with ISO9001, API6D, CE/ PED.

    We has established the technical research, development center and quality inspection center with a relatively sound management system.

    In addition, it has introduced advanced manufacturing technology from aboard, and has advanced machining centers, CNC machine tools, metal cutting and processing equipment, physical and chemical testing equipment, nondestructive tester, spectrum analyzer, valve comprehensive performance tester and other equipment to ensure the products reach the purpose of zero leakage.

    We insist on the concept of ” Quality first,Prestige important”, a well-trained and dedicated team including engineers,technicians and other employees, This allows us to offer customers quality product,competitive price and prompt delivery time.

    We always work hard to improve our existing products and pursue new ideas and ways to stay ahead of the every changing market.With our professonal and experience hope can enlarge your market and obtain a new brilliance in the future .



    How to disable the AC running all the time when using the defrost or defrost+floor vent positions. This was done in a 2001 Civic, in the later years (2003ish to 2005) the AC light operates a bit differently but the same problem is there and this procedure still applies. This is the procedure for the 2001-2005 Civic, for the 2006 to 2011 Civic check my other video.

    1. Turn the fan knob to the ON position.

    2. Switch to the FACE ONLY vent mode (or DEFROST mode if returning back to factory settings).

    3. Turn the temp knob to the HOT setting.

    4. Hold down the RECIRCULATION and A/C buttons simultaneously.

    5. While holding those two buttons, turn the ignition switch to the RUN position (you don’t have to start the car).

    6. Keep holding them down until the light stops flashing/goes solid, then release them.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the House

    WhatsApp Online Chat !