Automatic Temperature Regulating Agent Series is a kind of thermal expansion materials, which depends on principles that the substance expands when it is heated and constricts when it is cooled and a liquid is incompressible. It can automatically regulate temperature. When the ambient temperature goes up to the special value, Automatic Temperature Regulating Agent goes up to the special temperature with the ambient temperature, its unit volume increases. When the ambient temperature falls down to special value, Automatic Temperature Regulating Agent also falls down to the special temperature with the ambient temperature, its unit volume reduces. The agent is loaded in the purpose-made thermostatic element. The variation of ambient temperature takes a pressure and the thermostatic element takes a change, and this change brings the movement of either the appurtenance of the thermodynamic component or itself, thereby carrying out the automatic opening & closing function. All sorts of temperature controllers and the electrical switches are developed depending on the physical feature of Automatic Temperature Regulating Agent. It has been widely used in the fields of refrigeration, auto-control system, automobile industry, petrochemical industry, sanitary ware, heating and ventilating, electric electron, building, space & aviation etc.
|
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
||||||
|
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
|||||
|
A30-1 |
Powder, Cream |
30/40 |
7 |
Non. |
Non. |
|||
|
A30-2 |
Powder, Cream |
30/40 |
10 |
Non. |
Non. |
|||
|
A30-3 |
Powder, Cream |
3045 |
10 |
Non. |
Non. |
|||
|
A30-4 |
Powder, Cream |
30/60 |
8 |
Non. |
Non. |
|||
|
A30-5 |
Powder, Cream |
30/65 |
4 |
Non. |
Non. |
|||
|
A30-6 |
Powder, Cream |
30/85 |
10 |
Non. |
Non. |
|||
|
A32 |
Powder, Cream |
32/60 |
4 |
Non. |
Non. |
|||
|
A33 |
Powder, Cream |
33/45 |
6 |
Non. |
Non. |
|||
|
A35 |
Powder, Cream |
35/45 |
5 |
Non. |
Non. |
|||
|
A35-1 |
Powder, Cream |
35/45 |
10 |
Non. |
Non. |
|||
|
A35-2 |
Powder, Cream |
35/50 |
8 |
Non. |
Non. |
|||
|
A36 |
Powder, Slice , Column |
36/62 |
5.5 |
Non. |
Non. |
|||
|
A37 |
Powder, Slice , Column |
37/47 |
9 |
Non. |
Non. |
|||
|
A38 |
Powder, Slice , Column |
38/50 |
7 |
Non. |
Non. |
|||
|
A40 |
Powder, Slice , Column |
40/50 |
7 |
Non. |
Non. |
|||
|
A40-1 |
Powder, Slice , Column |
40/50 |
10 |
Non. |
Non. |
|||
|
A40-2 |
Powder, Slice , Column |
40/64 |
4 |
Non. |
Non. |
|||
|
A40-3 |
Powder, Slice , Column |
40/80 |
8 |
Non. |
Non. |
|||
|
A42 |
Powder, Slice , Column |
42/68 |
5 |
Non. |
Non. |
|||
|
A43 |
Powder, Slice , Column |
43/48 |
6 |
Non. |
Non. |
|||
|
A43-1 |
Powder, Slice , Column |
43/55 |
7 |
Non. |
Non. |
|||
Product detail pictures:

Our company insists all along the quality policy of "product good quality is base of enterprise survival; buyer fulfillment will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" and also the consistent purpose of "reputation very first, shopper first" for Good Quality for Low Temperature Wax to France Factories, The product will supply to all over the world, such as: Surabaya , Burundi , Lithuania , Each product is carefully made, it will make you satisfied. Our merchandise in the production process have got strictly monitored, because it is only to supply you the best quality, we'll feel confident. High production costs but low prices for our long-term cooperation. You can have a variety choices and the value of all types are same reliable. If you have any question, do not hesitate to ask us.
Dryer won’t heat, is too hot, won’t start/stop or not drying clothes? This video demonstrates how to test a cycling thermostat on an electric or gas dryer. The cycling thermostat is a commonly replaced part for a dryer that won’t heat or is taking too long to dry.
Other commonly replaced parts for a dryer that won’t heat are:
Gas solenoid valve
Dryer igniter
Heating element
Flame sensor
High limit thermostat
Cycling thermostat
Main control board
Timer
Click here to purchase a replacement dryer cycling thermostat:
https://www.repairclinic.com/Shop-For-Parts/a8c24/Dryer-Thermostat-Parts?TLSID=1873
Click here to purchase the multimeter used in this part testing video:
https://www.repairclinic.com/PartDetail/Digital-Multimeter/DM10T/964740?TLSID=1873
How to disassemble your dryer:
https://www.youtube.com/watch?v=2bVoelV7M7Y?TLSID=1873
For more DIY videos including part replacement and help finding your model visit the repair help section of our website:
https://www.repairclinic.com/RepairHelp/Dryer-Repair-Help?TLSID=1873
All of the information provided in this part testing video is applicable to the following brands: Amana, Frigidaire, GE, Kenmore, LG, Maytag, Roper, Samsung and Whirlpool.
RepairClinic has millions of replacement parts for appliances, lawn equipment, power tools, and heating & cooling equipment including washers, dryers, dishwashers, refrigerators, lawn mowers, snowblowers, furnaces, and air conditioners. Our customer care team is available to help by phone or live chat, seven days a week: 1-800-269-2609. We guarantee the fastest shipping possible—all in-stock parts ship the same business day. Return any part for any reason with our generous 365-day return policy.
In addition to providing replacement parts, RepairClinic.com offers free online troubleshooting information and DIY repair videos. Use our website to choose from a series of problems to discover the likely causes and the correct replacement part(s) for your particular model. Once you’ve determined the solution, our expertly-produced video tutorials will guide you through every step of the repair.
At RepairClinic, we make fixing things easy!
Connect With Us!
https://plus.google.com/+repairclinic
https://www.facebook.com/RepairClinic
https://www.twitter.com/RepairClinic
https://pinterest.com/RepairClinic/
Join our free VIP email list for discounts and money-saving tips: https://tinyurl.com/pnnh3be
Check out our blog: https://www.DIY.RepairClinic.com
Don’t forget to like and comment on this video, and subscribe to our channel!
In this veide we show you how to remove air pocket by bubbles from the engine cooling systen. Failure to BLEED the Cooling System on a automobile Engine that is recommended to do-so will cause failure to engine and improper operation. Failure to BLEED the Cooling System can cause Ignition KNOCK”PING” which could lead to cracks appearing inside the Engine Block, Inside the Cylinder Head Combustion Chamber water/coolant jacket and Apply poor heating to the passenger compartment during extreme Cold weather climate. Have a LOOK at HOW-TO relieve the AIR bubbles or AIR pocket that maybe trap inside the Engine Cooling System. Many of Today`s automobile Engine are Air Bleed in the same manner illustrated in this Video. When Air Bleed a cooling System, All hoses and gaskets must be pressure tight, No leak must be found on the System or the Air Bleeding procedure will fail. the Cooling System must be Pressure TEST with a Radiator Pressure Tester Tool at 28psi. The Radiator CAP must be pressure TEST at 17psi. ALWAYS AIR-BLEED THE COOLING SYSTEM WHEN IT IS COOL, and NEVER HOT or WARM. HOT COOLANT CAN CAUSE 2ND DEGREE BURN TO THE SKIN. NEVER PERFORM ANY SERVICE TO A HOT TEMPERATURE ENGINE.
How to Air-Bleed Cooling System for Automobile. Feature is the 2004 Nissan Frontier SE 4×4 with a V6(VG33E) Engine. Other makes and model like the Nissan Xterra, Pathfinder and other Infiniti Automobile products. Most Automakers will feature a REVERSE COOLING SYSTEM which always require Air-Bleeding to achieve 100% efficient Cooling Ability.
How to lower engine coolant operation temperature https://www.youtube.com/watch?v=lmP4PM-56eM .