Massive Selection for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Albania Manufacturers

Massive Selection for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Albania Manufacturers

Short Description:

Product Detail

Product Tags

We intention to see quality disfigurement within the creation and supply the ideal support to domestic and overseas buyers wholeheartedly for Trv Radiator Valves, Radiator Valve Extension, Home Automation Temperature Control, We've been not pleased while using the present achievements but we are trying finest to innovate to satisfy buyer's much more personalized needs. No matter where you will be from, we have been here to wait for your sort ask for, and welcom to go to our manufacturing facility. Choose us, you can meet your trusted supplier.
Massive Selection for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Albania Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Massive Selection for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Albania Manufacturers detail pictures


We have been experienced manufacturer. Wining the majority of your crucial certifications of its market for Massive Selection for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Albania Manufacturers, The product will supply to all over the world, such as: Ghana, Zimbabwe, Islamabad, Our company now has many department, and there have more than 20 employees in our company. We set up sales shop, show room, and product warehouse. In the meantime, we registered our own brand. We have tightened inspection for quality of product.



  • 24″ 600# ball valve. The valve weighs over 14000 lbs. Torque required is approx 500000 in/lbs. Actuator is rated for 600000 in/lbs (50000 ft/lbs) torque. It is 1 of …



    Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster
    462 Wide Open Throttle (WOT) Position Signal – Diesel Engine Only follow me on twitter https://twitter.com/fupabox

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    WhatsApp Online Chat !