New Delivery for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Haiti Manufacturers

New Delivery for
 TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Haiti Manufacturers

Short Description:

Product Detail

Product Tags

Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for Corner Radiator Valves , Thermal Actuator Unit , Air Compressor Parts , We are keeping chasing WIN-WIN situation with our clients. We warmly welcome clients from all over the world coming over for a visit and establishing long term relationship.
New Delivery for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Haiti Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

New Delivery for
 TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Haiti Manufacturers detail pictures


abide by the contract", conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for New Delivery for TU-1J90 thermal wax actuator for industrial thermostatic water regulations mixing valve for Haiti Manufacturers, The product will supply to all over the world, such as: Greek , Nepal , Lesotho , Our company absorbs new ideas, strict quality control, a full range of service tracking, and adhere to make high-quality products. Our business aims to "honest and trustworthy, favorable price, customer first", so we won the trust of the majority of customers! If you are interested in our products and services, please do not hesitate to contact us!



  • Our USA CA regular customer last year (Oct 2015)Placed another order for several sets of machines including drying oven model YX-D10 Ten meters rotary tunnel for drying washed bottles + model YX-AB100 semi automatic tubes filling sealing machine+two sets YX-PMC series blending tanks for shampoo as well as the jars capping machine linear capper model YX-AC60; Last Decemeber we finished all the machine and kept them ready in our stock .
    Three month later our customer called us for the pickup of these machine in our factory and shipped them to LA port . We soon wooden case the machines and cleaned all the machines before loading them into one 40ft container .
    As below there is the basic information for the machines respectively;
    Technical Parameters 1000L Electric Heating Blending Tank
    1. Full Capacity: 1200 Liters
    2. Processing Capacity: 1000 Liters
    3. Emulsification Part: with 11kw (Motor of Siemens), fixed speed of 2800RPM
    4. Scraping blending: with 5.5kw Motor of Siemens, rotation speed
    Of 20-60 RPM, with inverter of Delta for speed adjustment.
    5. Three layer type tank with heating and cooling equipment
    (1) Inner Layer: SUS#316 4m/m
    (2) Intermediate Layer: SUS#304 4m/m (spiral Diversion layer)
    (3) Outer Layer: SUS#304 2m/m (heat preservation cotton)
    6. Material discharging adopts tank bottom valve (2 inches)
    Discharging.
    7. Electric heating (1) heating rod with 36kw power (18*2groups)
    8. Work platform adopts SUS#304
    9. Operating control box adopts SUS#304
    (1) Ampere meter and voltmeter
    (2) Variable-frequency governor
    (3) Temperature control and display
    Other component controlling switches
    10. Material
    (1) Contact part with liquid: SUS#316
    (2) Other parts: SUS#304
    300L blending tank basic data as below :
    Technical Parameters
    1. Full Capacity: 350 Liters
    2. Processing Capacity: 300 Liters
    3. Emulsification Part: with 4kw (Motor of Siemens), fixed speed of 2800RPM
    4. Scraping blending: with 2.2kw Motor of Siemens, rotation speed
    Of 20-60 RPM, with inverter of Delta for speed adjustment.
    5. Three layer type tank with heating and cooling equipment
    (1) Inner Layer: SUS#316 3m/m
    (2) Intermediate Layer: SUS#304 3m/m (spiral Diversion layer)
    (3) Outer Layer: SUS#304 2m/m (heat preservation cotton)
    6. Material discharging adopts tank bottom valve ((2 inches)
    Discharging.
    7. Electric heating (1) heating rod with 18kw power (9*2groups)
    8. Work platform adopts SUS#304
    9. Operating control box adopts SUS#304
    (1) Ampere meter and voltmeter
    (2) Variable-frequency governor
    (3) Temperature control and display
    Other component controlling switches
    10. Material
    (1) Contact part with liquid: SUS#316
    (2) Other parts: SUS#304
    Applicable Products
    1) Cosmetics
    Skin cream, shaving cream, shampoo, toothpaste, cold cream, cold sun cream, cleanser, moisture cream, detergents, serums, moisturizers, hand cream and so on.
    2) Daily chemical
    Laundry detergent, hand sanitizer, toilet clean, automotive glass washer fluid and so on.
    3) Pharmacy Industry
    Latex, emulsions, salves (ointments), oral syrup, oral liquid and so on. 4) Food Industry
    Sauce, cheese, nutrient solution, infant food, chocolate, saccharides and so on.
    5) Chemical Industry
    Latex, sauce, saponification products, paints, coatings, resins, adhesives, lubricants and so on.
    Use &Operation of blending tanks
    1.Emulsifying Temperature: to adjust and control the inner material temperature of the emulsifying tank. It is set according to the temperature requirement of customers’ actual production materials.
    2.Emulsifying Current: The current display when the emulsifying motor works.
    3.Homogenizing Current: The current display when the homogenizing motor (blending motor) works.
    4.Homogenizing time: The working time of the homogenizing motor. It should be noted that the working time should not exceed 5 minutes.
    5.Generally, 5 minutes’ emulsifying time is enough, if longer time is required, it is recommended to start after 10 minutes.
    6.Emulsifying Speed: Controls the speed of the blending blades, for which when rotated clockwise, the speed goes up.
    7.Emulsifying Heating: with total 4 switches for two groups of heating, one or two groups can be turned on based on actual heating requirements.
    8.Homogenizing: Press the red button to start the up blending function and press again to stop.
    9.Emulsify: Press the red button to start the bottom emulsifying function with the emulsifying time already set to 5 minutes.
    For more information about the various machines filling packing equipments like YX-PMC series Blending tanks 300L mixing equipment 1000L lotion shampoo mixer equipment for USA market tanque de mezcla champú from our superb cosmetic machinery factory,plz browse our another website business video https://youtube.com/user/mrjackdu007 as well as follow PENGLAI INDUSTRIAL CORP business website https://penglaichina.com



    ***VISIT OUR SPONSORS***
    https://www.traderadiators.com | https://www.grahamplumbersmerchant.co.uk | https://www.buteline.com/uk | https://www.adey.com | https://celebrate200.co.uk

    This video covers s plan heating systems and 2 port valves. This includes their plumbing, their wiring, how they are controlled with time clock programmers and thermostats. For more information visit https://www.plumberparts.co.uk

    We all have dreams. Some of them are nightmares, some of them aren’t. But then suddenly, out of nowhere, you wake up and I arrive like a bolt out of the blue to tell you about today’s plumberparts.co.uk video. We’re gonna look at S Plan systems today and the 2 port valve that’s absolutely integral in an S Plan system. So get ready for the wildest journey of your plumbing life. Let’s just go. So an S Plan heating system is just another way of controlling where hot water goes from the boiler. It can either go to the indirect hot water coil on the cylinder to heat hot water up that’s gonna come out the taps, or it can be diverted off to heating radiators or you can have another valve that diverts off to underfloor heating or even another zone for another radiator, all individually controlled by different thermostats and time clocks.
    Today we’re gonna look at the very simplest type of S Plan that you can have. That is, we’ve got one valve here that goes off to the hot water cylinder and one valve here that goes off to the radiators. But before we start, as ever, don’t do any work on electrics if you’re not happy and competent and you don’t have an electrical tester. Always make sure everything’s turned off. Always, before you remove a wire or anything like that test and make sure it’s dead, okay? Because otherwise that how you’ll end up. Dead!
    First, let’s have a little wee look at the electrics. So with this cover off, here. Now as you can see, sometimes you’ll go to places and the wiring’s just bonkers. You know, look at that, you might think, “God, where does everything go?” But if you isolate each one like we did on the 3 Port system that I showed you a few weeks ago in the videos, we’ll be able to find out where to remove each wire and where to put the new one in for the new valve. Get yourself a bit of paper and write down everything, every colour, and what block it goes to, and where it runs off to, okay? Now, there is a common principle with all control valves, that they need to be open and signal the boiler only once they’re open to tell the boiler and the pump to come on. If that wasn’t there, the boiler and pump could come on with the valves shut and have nowhere to dissipate their heat, could crack boiler sections and cause leaks and basically a whole hubbub of hell. Fortunately, all the manufacturers have thought of this, so when you do your wiring, you have your earth, your neutral, then you have a live feed to the motor itself so when the thermostat calls for heat and everything it will send a live to this and the motor will motor around, and then it has two wires left. Now, it’s a switch, basically, that’s all it is. There’ll always be a constant live to this. This is why when you need to test for electrics in these things you need to be careful and make sure the constant permanent live is dead, cause it’s a switched live. The only way you’ll ever do that is to wire set the whole system electronically by turning it off and removing the fuse. Now, you have the live supply, you have the permanent live comin’ in on one wire. When the valve opens up, it touches a smaller marker switch and sends a live back down this wire to the boiler and the pump to tell them to come on. It’s the same on all these valves, okay? Sometimes the wires on different valves are different colours, but generally nowadays they’ve tried to make them so they’re all the same so it’s easier for you to change. If it is different, have a little look at the book that was supplied with the valve and make sure the wires go in the right place, then. Let’s have a look at this S Plant system in situ. We’ll also describe that at the office in a second. We have our boiler flow coming from here. It goes up there, just across the top to the pump, which you can see just here, and then it comes down to this T here. Now it can either go off by this valve, off to the hot water cylinder to heat the hot water or by the faulty valve that we’re removing to the heating system. That’s basically how an S Plan system works. They’re generally controlled by a programmer and a series of thermostats. The good thing about an S Plan system is you can have as many different zones as you like. So you can have, as I said, underfloor, different radiator zones, different cylinder zones, things like that, which make it a lot easier to control the services in your home.
    Let’s just have a quick look, schematically, about how these systems work. Imagine we have our boiler here, with our pump flowing water in that direction.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    WhatsApp Online Chat !