OEM/ODM Factory for Thermostatic Wax Linearity Series for Southampton Factory
Short Description:
Product Detail
Product Tags
OEM/ODM Factory for Thermostatic Wax Linearity Series for Southampton Factory Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
|
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
|
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility sAcid and Alkali |
Mechanical Impurity |
||
|
B-5-1 |
Liquid |
-20/-5 |
≥7 |
Non. |
Non. |
|
B0-1 |
Liquid |
-15/0 |
≥7 |
Non. |
Non. |
|
B5-1 |
Liquid |
-10/5 |
≥7 |
Non. |
Non. |
|
B15-1 |
Liquid |
0/15 |
≥7 |
Non. |
Non. |
|
B20-1 |
Semisolid |
5/20 |
≥7 |
Non. |
Non. |
|
B25-1 |
Semisolid |
10/25 |
≥7 |
Non. |
Non. |
|
B30-1 |
Semisolid |
15/30 |
≥7 |
Non. |
Non. |
|
B35-1 |
Semisolid |
20/35 |
≥7 |
Non. |
Non. |
|
B40-1 |
Powder, Slice , Column |
25/40 |
≥7 |
Non. |
Non. |
|
B45-1 |
Powder, Slice , Column |
30/45 |
≥7 |
Non. |
Non. |
|
B50-1 |
Powder, Slice , Column |
35/50 |
≥7 |
Non. |
Non. |
|
B55-1 |
Powder, Slice , Column |
40/55 |
≥7 |
Non. |
Non. |
|
B60-1 |
Powder, Slice , Column |
45/60 |
≥7 |
Non. |
Non. |
|
B65-1 |
Powder, Slice , Column |
50/65 |
≥7 |
Non. |
Non. |
|
B70-1 |
Powder, Slice , Column |
55/70 |
≥7 |
Non. |
Non. |
|
B75-1 |
Powder, Slice , Column |
60/75 |
≥7 |
Non. |
Non. |
|
B80-1 |
Powder, Slice , Column |
65/80 |
≥7 |
Non. |
Non. |
|
B85-1 |
Powder, Slice , Column |
70/85 |
≥7 |
Non. |
Non. |
|
B90-1 |
Powder, Slice , Column |
75/90 |
≥7 |
Non. |
Non. |
|
B95-1 |
Powder, Slice , Column |
80/95 |
≥7 |
Non. |
Non. |
Product detail pictures:

Our pursuit and enterprise aim would be to "Always fulfill our buyer requirements". We carry on to acquire and layout excellent quality items for the two our old and new clients and realize a win-win prospect for our shoppers in addition as us for OEM/ODM Factory for Thermostatic Wax Linearity Series for Southampton Factory, The product will supply to all over the world, such as: America , Slovak Republic , Sydney , we sincerely hope to establish a good and long-term business relationship with your esteemed company through this opportunity, based on equality, mutual benefit and win-win business from now to the future. "Your satisfaction is our happiness".
Ideal Boiler Function + Flame Sensor & Gas Ionisation
Some faults below
LE means the control unit is faulty IF it does not clear with power off, wait 10 seconds, then reset and retest.
LF means the control unit did not see a flame, it will try 3 times. No Gas, Faulty Gas Valve, Faulty Spark or electrode in video faulty
LA means Overheat error, possible pump failure or temp sensor.
L8 means Fan Error
H1 means Central Heating ‘flow’ temperature sensor error
H2 means Central Heating flow’Return’ temperature sensor error
H3 means Domestic Hot Water temp sensor error
H4 means Dry Fire temp sensor error
H5 means the jumper pins are in the wrong position or missing
HF Flame Detection error
If you have very bad poor IDLE on your Honda civic the first thing that you have to try:
1. Check coolant level. .
Plug troubleshoting odb2 computer (diagnostic tool) and read error codes if it will say that you have P0300 P0301 etc. misfire
2. Check your spark plugs
3. Check ignition Coils
sometimes it will or can detect crankshaft sensor position wrong sometimes not
anyway !!!
if it’s still does the same consider replacing your crankshaft and camshaft sensors they are very important because they determine position of the engine.