OEM/ODM Factory for TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve to Germany Manufacturer
Short Description:
Product Detail
Product Tags
OEM/ODM Factory for TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve to Germany Manufacturer Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

We pursue the administration tenet of "Quality is remarkable, Services is supreme, Status is first", and will sincerely create and share success with all customers for OEM/ODM Factory for TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve to Germany Manufacturer, The product will supply to all over the world, such as: Brunei , Mecca , Somalia , Abiding by our motto of "Hold well the quality and services, Customers Satisfaction", So we provide our clients with high quality products and excellent service. Please feel free to contact us for further information.
If you’re in the San Diego area and need help with your sprinklers or lawn care, please contact Dave and Aqua Tech Sprinkler Repair.
PHONE: (760) 436-3050
EMAIL: aquatechsol@gmail.com
WEBSITE: https://aquatechsprinklerrepair.com
FACEBOOK: https://tinyurl.com/sprinklerman
SUBSCRIBE: https://tinyurl.com/aquatube
Have you ever wondered how your sprinkler system works? In this video, Dave gives us the breakdown of the valve systems—what they do and how they work.
You’ll learn a lot about those parts of your sprinkler system that you see on a regular basis, but aren’t sure what their purpose is or how they function.
Parts of your sprinkler system that are discussed:
• Anti-siphon valves—These valves prevent water from flowing back into your sprinkler system and causing a backup.
• Solenoid—This is a feature of your sprinkler system that deals with the electronic functioning, such as charging the clock or sending an electrical charge from the controller to the valve which opens up the diaphragm.
• Flow Control—With this valve you can control the flow of water by turning it down or up as needed. Usually, you are able to turn water down about 85-90%, but it is abnormal for it to turn all the way off.
• Bleeder valve—If you have debris built up in your valves, the bleeder can flush them out and clear that debris. If you notice leaking valves, take a screwdriver and open the bleeder valve slightly to flush out the diaphragm in case debris has found its way in there. Make sure you close it tightly!
• Diaphragms—The diaphragm opens and then releases the water to go to your sprinkler head. If the diaphragm is old, blown out, or otherwise damaged, the clock will no longer be able to control it and your watering will not occur with the precision that it may be set for. Bad diaphragms are quite common—making up the bulk of Dave’s calls.
Replacing valves can be tricky, which is why the best way to replace one is to give Dave a call. He’ll come out and give you a free estimate on what it will take to get your sprinkler system working in tip top shape again!
This video was produced by Simple Business Video Marketing
Generate quality leads online with simple videos
https://www.simplebusinessvideomarketing.com
The valves manufactured and sold by ETM ARMATUREN.
ETM trade mark:ETMARMATUREN,ETM,ETMVAL,欧罗泰克.
ETM products including:
DIN Standard bellows sealed stop valves (Straight-Through Type)
DIN Standard Bellows Sealed Stop Valves (Angle Type)
DIN Standard Long Life-Heavy Duty Bellows Sealed Stop Valves
DIN Standard Gland Packing Globe Valves ( Straight-Through Type)
DIN Standard Gland Packing Globe Valves (Angle Type)
DIN Standard F4 Gate valves (Length acc.to DIN EN 558-1,face to face series 14)
DIN Standard F5 Gate Valves (Length acc.to DIN EN 558-1,face to face series 15)
DIN Standard F7 Gate Valves (Length acc.to DIN EN 558-1,face to face series 26)
DIN Standard Swing Check Valves (Length acc.to DIN EN 558-1,face to face series 48 & series 1)
DIN Standard Lift Check Valves
DIN Standard Y Type Strainer
Furthermore we can manufacture and process the specifical valve upon customer’s request.
ETM all valves comply to Pressure Equipment Directive 97/23/(PED),CE Marking.
ETM insists on the spirit of Deploitation , innovation, factualism and struggling, with the flexible management system. We aim to supply the qualified products and pro-service and after-service which will satisfy you. Welcome visit to ETM.
Gate Valves (F5 Type)
DIN Standard F5 Gate valves / (Length acc.to DIN EN 558-1,face to face series 15 )
DIN F5 Gate valve
DIN Absperrschieber F5
DIN Válvulas de compuerta F5
DIN F5 šoupátko stavební délka dle DIN EN558-1 serie 15
DIN Standard F5 sluseventil (lengde iht. DIN EN 558-1, bygge lengde serie 15)
DIN Standardında F5 Sürgülü Vana
Van cổng chuẩn DIN kiểu F5
ETM Code No. : ETM FIG.F.161, ETM FIG.F.162
This ETM gate valve can be used in Industry, Powerstations, Flue gas purification plant, processing technology, gas supply,
vapor facilities, thermal oil applications, recycling facilities, vacuum facilities, ammonia, hot water, heating technology, district
heating, cooling and freezing systems, general plant manufacturing, steam systems.
All ETM valves – is classed leak rate “A” in accordance with EN 12266-1.
Products:
ETM-FIGURE F-BS/EN Standard F5 gate valve PN 16 Bar with Flanges According to DIN EN 1092-1
ETM-FIGURE F-BS/EN Standard F5 gate valve PN 25 Bar with Flanges According to DIN EN 1092-1
ETM-FIGURE F-BS/EN Standard F5 gate valve PN 16 Bar with Butt Weld Ends According to DIN EN 12627
ETM-FIGURE F-BS/EN Standard F5 gate valve PN 25 Bar with Butt Weld Ends According to DIN EN 12627
Material Equivalence:
EN Material Name———————–EN Number ————Forgings—————–ASTM Material——————-Forgings
EN 10213 GP240GH———————1.0619——————1.0460—————–ASTM A216 WCB—————–A105
EN 10213 G20Mo5———————–1.6220——————1.0437—————–ASTM A352 LCB——————A352 LF2
EN 10213 G17CrMo5-5——————1.7357——————1.7335—————–ASTM A217 WC6—————–A182 F11
EN 10213 G17CrMo9-10—————-1.7379——————1.7380 —————-ASTM A217 WC9—————–A182 F22
EN 10213 GX5CrNi19-10—————-1.4308——————1.4301—————–ASTM A351 CF8—————–A182 F304
EN 10213 GX5CrNi19-11-2————-1.4408 —————–1.4401—————–ASTM A351 CF8M—————-A182 F316
Features:
Cast steel PN16 ,PN25, DN40 to DN1000
Length acc.to DIN EN 558-1,face to face series 15 (DIN3202 series F5)
Rising, non rotating stem
Non rising stem
Welded seat in stellite or Cr-steel
Solid stem make of stainless material
Full port design Full length wedge guides
Stem sealing in graphite Raised, turning stem
Back sealed stem Welded seat in stellite or Cr-steel
High-tensile Gland Packing Self adjusted gland
Top Flange to ISO 5210
Gear operated
Electric actuator
Position indicator
Locking / interlock
Stem protection
Stem extension
Drain plug
By pass
Mediums:
Standard: Steam, gases, hot water, thermal fluids, hot oil, process water, etc.
Stainless Steel: Process water, aggressive media, etc.
Requirements and testing:
The test are carried out according to DIN EN12266-1
Shell test : nominal pressure (PN)X1.5
Tightness of seat :nominal pressure (PN)X1.1
Certificate of conformity in according to with PN-EN10204
Design according to PN-EN12516-2
Valves have been submitted for appraisal of conformity according to the directive pressure equipment directive 97/23/EC.
Installation:
They can be installed on pipelines in a vertical or horizontal and operation only when fully open or closed
Connection:
Butt-Welded according to EN12627,flanged according to EN1092-1 or to customer request
Face to face dimensions according to EN558-1 15 Series (DIN3202 Series F5)
Operation:
Handwheel (If required)
Electric actuator
Gear box
Flange ISO5210 (Ready for actuator)