OEM/ODM Supplier for TU-029 thermostatic cartridge wax sensor for sanitary ware to Durban Factories

OEM/ODM Supplier for
 TU-029 thermostatic cartridge wax sensor for sanitary ware  to Durban Factories

Short Description:

Product Detail

Product Tags

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our firm to the long-term to develop together with consumers for mutual reciprocity and mutual advantage for Where To Get Paraffin Wax , Wholesale Paraffin Wax Suppliers , Radiator Thermostat , We invites you and your company to thrive together with us and share a dazzling foreseeable future in world-wide market place.
OEM/ODM Supplier for TU-029 thermostatic cartridge wax sensor for sanitary ware to Durban Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

OEM/ODM Supplier for
 TU-029 thermostatic cartridge wax sensor for sanitary ware  to Durban Factories detail pictures


It can be our accountability to satisfy your preferences and competently provide you. Your satisfaction is our greatest reward. We are searching ahead towards your visit for joint growth for OEM/ODM Supplier for TU-029 thermostatic cartridge wax sensor for sanitary ware to Durban Factories, The product will supply to all over the world, such as: Thailand , Comoros , Lisbon , Our professional engineering group will always be ready to serve you for consultation and feedback. We're able to also offer you with absolutely free samples to meet your requirements. Finest efforts will likely be produced to offer you the ideal service and goods. For anyone who is thinking about our company and merchandise, be sure to contact us by sending us emails or contact us quickly. As a way to know our merchandise and firm. lot more, you can come to our factory to find out it. We'll always welcome guests from all over the world to our business to build company relations with us. Be sure to feel free to get in touch with us for business and we believe we've been intending to share the top trading practical experience with all our merchants.



  • The Pick Sanitary Heater is a 3-A authorized design and meets USDA & FDA requirements.

    The Pick heater body can be easily disassembled for periodic cleaning as may be called for by COP, or clean-out-of-place requirements. With its sanitary clamp design, the Pick mixing chamber can quickly be pulled from system piping at one steam and two liquid connections.

    Once the heater is removed the body can be completely broken apart. The helical flight, critical for thorough mixing of steam and liquid, neatly slides out from the assembly. The Pick steam injection tube can be removed, with access to the internal spring, piston and stopper achieved by taking out the retaining pin.

    Once the components of the heater body are cleaned and inspected, the Pick Sanitary heater body can be reassembled in a matter of minutes, and ready to be put back into service.



    NEW CONFIGURABLE NAAMS COMPONENTS FROM MISUMI USA!

    -~-~~-~~~-~~-~-

    Start configuring now! Visit https://www.misumiusa.com to get started!

    Robot Series Linear Actuators – Sizing & Selection

    Chuck Leonard, a Product Engineer with the MISUMI Motion Systems Group, will be presenting this webinar. With years of applications support experience in sizing and selection of actuators, he will cover Sizing, Applications, and how to configure our Robot Linear Actuators. .

    Key insights:

    • Sizing and selection process
    • Required design considerations and explanations
    • Multi-function programming capabilities
    • Controller, power supply and USB driver set-up
    • Stroke length
    • How to configure online with CAD download

    Feel free to contact Chuck in advance with your product questions or application needs at motionsystems@misumiusa.com

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    WhatsApp Online Chat !