Professional China Low Temperature Wax to Iraq Factory

Professional China 
 Low Temperature Wax to Iraq Factory

Short Description:

Product Detail

Product Tags

Using a total scientific good quality management process, superior high quality and excellent faith, we get great name and occupied this field for Wax Element , Wax Thermostat , Automotive Thermostat Housing , We will empower people by communicating and listening, Setting an example to others and learning from experience.
Professional China Low Temperature Wax to Iraq Factory Detail:

Automatic Temperature Regulating Agent Series is a kind of thermal expansion materials, which depends on principles that the substance expands when it is heated and constricts when it is cooled and a liquid is incompressible. It can automatically regulate temperature. When the ambient temperature goes up to the special value, Automatic Temperature Regulating Agent goes up to the special temperature with the ambient temperature, its unit volume increases. When the ambient temperature falls down to special value, Automatic Temperature Regulating Agent also falls down to the special temperature with the ambient temperature, its unit volume reduces. The agent is loaded in the purpose-made thermostatic element. The variation of ambient temperature takes a pressure and the thermostatic element takes a change, and this change brings the movement of either the appurtenance of the thermodynamic component or itself, thereby carrying out the automatic opening & closing function. All sorts of temperature controllers and the electrical switches are developed depending on the physical feature of Automatic Temperature Regulating Agent. It has been widely used in the fields of refrigeration, auto-control system, automobile industry, petrochemical industry, sanitary ware, heating and ventilating, electric electron, building, space & aviation etc.

Model Number

Appearance

(Normal Temperature)

Quality Standard

Range of Temperature Control

Effective Distance

Travel

Water-Solubility

Acid and Alkali

Mechanical Impurity

A30-1

Powder, Cream

30/40

7

Non.

Non.

A30-2

Powder, Cream

30/40

10

Non.

Non.

A30-3

Powder, Cream

3045

10

Non.

Non.

A30-4

Powder, Cream

30/60

8

Non.

Non.

A30-5

Powder, Cream

30/65

4

Non.

Non.

A30-6

Powder, Cream

30/85

10

Non.

Non.

A32

Powder, Cream

32/60

4

Non.

Non.

A33

Powder, Cream

33/45

6

Non.

Non.

A35

Powder, Cream

35/45

5

Non.

Non.

A35-1

Powder, Cream

35/45

10

Non.

Non.

A35-2

Powder, Cream

35/50

8

Non.

Non.

A36

Powder, Slice , Column

36/62

5.5

Non.

Non.

A37

Powder, Slice , Column

37/47

9

Non.

Non.

A38

Powder, Slice , Column

38/50

7

Non.

Non.

A40

Powder, Slice , Column

40/50

7

Non.

Non.

A40-1

Powder, Slice , Column

40/50

10

Non.

Non.

A40-2

Powder, Slice , Column

40/64

4

Non.

Non.

A40-3

Powder, Slice , Column

40/80

8

Non.

Non.

A42

Powder, Slice , Column

42/68

5

Non.

Non.

A43

Powder, Slice , Column

43/48

6

Non.

Non.

A43-1

Powder, Slice , Column

43/55

7

Non.

Non.


Product detail pictures:

Professional China 
 Low Temperature Wax to Iraq Factory detail pictures


We always think and practice corresponding to the change of circumstance, and grow up. We purpose at the achievement of a richer mind and body as well as the living for Professional China Low Temperature Wax to Iraq Factory, The product will supply to all over the world, such as: venezuela , Iraq , Wellington , Further, we are supported by highly experienced and knowledgeable professionals, who have immense expertise in their respective domain. These professionals work in close coordination with each other to offer our clients an effective range of products.



  • This is a first check if you have a GM vehicle with a 3800 engine that occasionally stalls. Sometimes the problem is as simple as cleaning an electrical connector.

    I cannot guarantee against unauthorized modifications of this information or improper use of this information. I assume no liability for property damage or injury incurred as a result of any of the information contained in this video. Be sure to read and follow all safety instructions for any equipment seen or implied in this video, and use safe practices when working with potentially dangerous equipment. No information contained in this video shall create any express or implied warranty or guarantee. Any injury, damage or loss that may result from improper use of these tools, equipment, or the information contained in this video is the sole responsibility of the user.



    How to backup data – IAI SEL type Controller – Electric Actuator

    https://www.intelligentactuator.com/x-sel-pc-interface-software-tutorial/

    Connection Confirmation…
    Setting of Two or more Program…
    Controller – All Data Backup – Save File As, etc…
    – see details on the video —

    The XSEL PC Software is used with IAI’s fully programmable controller line. These controllers include the X-SEL, ASEL, PSEL, and SSEL as well as many older SEL controllers. The XSEL PC software is fully programmable and can perform many of the same functions as a small PLC.

    Establishing Communications

    The software may display the menu above when the X-SEL PC Interface software is started. Notice that a few of the menu options are unavailable. This is an indication that the software was unable to communicate with the controller (i.e. you are off-line). This may be due to the serial communication cable that is not secure to the PC and/or the X-SEL controller. Also make certain that the controller is ready to communicate by having the Teaching Serial Interface Port switch in the “‘MANU” position.

    Once communications has been established, all menus should become available as shown in the image above. To reestablish communications if accidentally lost, go to the ‘”Controller” menu and drop to “Reconnect”. The software will attempt to reestablish communication.

    Clearing Common Errors

    A possible error that may occur is the “EE6C-DO output current error”. This error is indicating that the digital IO card not being supplied 24VDC. In this case, it is important to check the wiring, polarity and 24V power supply to the controller as shown in the X-SEL Operation Manual. The error may also occur if the controller powers up before the 24VDC is applied to the controller. Once this error has occurred, it will persist until the controller is reset. The error will also be displayed on the 4-digit 7-segment display on the controller.

    Another error that may occur is the “ErG” error, that is indicated only the 4-digit 7-segment display of the controller. This error is simply e-stop. The X-SEL controller has a dedicated e-stop terminal at the System IO connector. This should be normally closed contact. While the controller is in Manu mode the e-stop connection of the Teaching/Communication Port becomes active. Also check the e-stop button of the IAI serial communication cable to release e-stop.

    Another error that may occur is the “ECA1- ABS Data Backup Battery Voltage Low Error (Driver)” error. This error is encountered on an X-SEL system equipped with absolute encoders. The following section will discuss this situation in greater detail.

    Homing

    The “ECA1″ error will be encountered on a X-SEL equipped with absolute encoders. This error is an alert that the absolute encoders have lost battery power resulting in a loss of positional information. The power loss may be due to a dead battery. In most cases, however, it is simply caused by disconnecting the encoder from the controller. The encoder battery is located on the controller for easy replacement. Once reconnected, the absolute encoders will have to be reset/homed to clear this error.
    Absolute Encoder Reset Menu
    Absolute Encoder Reset Menu

    The Absolute Encoder Reset Menu provided a quick and easy way to reset the encoders. To open this window go to the “Controller” menu and select “ABS. Encoder Reset”. At the top of the window, there is a drop-down menu that allows you to select the axis (1,2,3 or 4 depending on the system). Once an axis is selected simply click on the button indicated by the red arrow. As you progress the arrow will move next button indicating when the next step should be executed. Once all axis are reset go to the “Controller” menu and select “Software Reset”. This will reset the controller which completes the homing procedure.

    In the case of incremental encoders, the actuators would have to be homed every time that the controller powered up. This can be done with the “HOME” command in a program or it can be done through the point menu (see below). During e-stop the encoders maintain encoder power, making homing afterward unnecessary.

    Points

    The point table stores all positional information. The controller can store up to 3000 unique points. This menu will also provide servo control so that motors can be turned on, off, jog in both directions and move to taught positions on all selected axis or specific axis.

    Consider this window as a snapshot of what is stored on the controller. Anything that is typed on this window will not automatically be stored in the controller. The icon “Transmit to Controller” must be used to store the information in the controller. The prompt “Write to FLASH ROM?” asks the information should be stored in Flash ROM or RAM memory….

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Key

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    WhatsApp Online Chat !