Professional Design TU-029 thermostatic cartridge wax sensor for sanitary ware Supply to Australia

Professional Design
 TU-029 thermostatic cartridge wax sensor for sanitary ware  Supply to Australia

Short Description:

Product Detail

Product Tags

We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for Thermal Actuator Efficiency , Industrial Wax Suppliers , Wax Element Temperature Control Valve , Our corporation maintains risk-free enterprise combined by truth and honesty to maintain long-term interactions with our clients.
Professional Design TU-029 thermostatic cartridge wax sensor for sanitary ware Supply to Australia Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Professional Design
 TU-029 thermostatic cartridge wax sensor for sanitary ware  Supply to Australia detail pictures


High-quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is constantly observed and pursued by our business for Professional Design TU-029 thermostatic cartridge wax sensor for sanitary ware Supply to Australia, The product will supply to all over the world, such as: Hamburg , Afghanistan , Turin , The best and original quality for spare parts is a most important factor for transportation. We may stick on supplying original and good quality parts even a little profit earned. God will bless us to do kindness business forever.



  • Just a quick intro. Move videos to follow. Please see my playlist for the full series titled 1977 to 1993 Bosch C.I.S. Gas Fuel Injection. https://www.youtube.com/playlist?list=PLtRKk64pu2wp1txgW4sOqs7ErB2ilIRmt
    A solution to this particular problem is covered in Kent’s on demand video available on his website : https://mercedessource.com/store/solving-rough-idle-and-low-rpm-startup-a-1986-1993-cis-engine-demand-video
    Common symptoms are rough running at startup and low idle speed. CIS was installed on the following models. You saw CIS injection on the 4, 6, and 8 cylinder engines that were installed in the 107 Chassis 450SL 450SLC 380SL 560SL 1977 to 1989, 116 chassis 450SE 450SEL 280SE 280SEL 6.9 1977 to 1980, 123 chassis 1977-1985 Models 230E 280E 280CE, 126 chassis 380SE 380SEL 500SEL 300SDL 420SEL 300SE, 300SEL 560SEL 380SEC and 560SEC 1981-1991, 201 Chassis 190E 1984 to 1993 and 124 Chassis 260E 300E 300TE 300CE 400E 500E 1986 to 1993, and the R129 chassis 300SL and 500SL 1990 to 1993. Only the models after 1985 would have these specific problems together.



    Sometime a gasoline engine will leak coolant with out any appearance or display of liquid on the floor. Here we Diagnose a Slow UN-detectable Coolant leak from the Nissan VG33E V6 engine. Sometime pressure testing a cooling system will not reveal any coolant leaks. But in this video we will show you a common location for a slow coolant leak on the Nissan 60 degree 3300 V6 engine.

    How to find a coolant leak by visible inspection?.

    HOW TO REMOVE UPPER PLENUM INTAKE MANIFOLD. https://www.youtube.com/watch?v=vjL24ojaYtM

    HOW TO REMOVE LOWER INTAKE RUNNER PLENUM MANIFOLD. https://www.youtube.com/watch?v=7TvQF3wWQQQ

    NISSAN PCV RE-ROUTING TO BETTER BREATHER SYSTEM. https://www.youtube.com/watch?v=ZZ6eC3KsOXM

    THANM YOU FOR YOUR VIEWER SHIP.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !