Quality Inspection for TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Florida Importers

Quality Inspection for
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Florida Importers

Short Description:

Product Detail

Product Tags

We're also concentrating on improving the things administration and QC program to ensure we could maintain terrific gain from the fiercely-competitive company for Wax Motor Dishwasher , Thermostatic Wax , Danfoss Thermal Wax Actuator , We keep on with supplying integration alternatives for customers and hope to create long-term, steady, sincere and mutual advantageous interactions with consumers. We sincerely anticipate your check out.
Quality Inspection for TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Florida Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Quality Inspection for
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Florida Importers detail pictures


Persisting in "High quality, Prompt Delivery, Aggressive Price", we have established long-term cooperation with clientele from both equally overseas and domestically and get new and old clients' higher comments for Quality Inspection for TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Florida Importers, The product will supply to all over the world, such as: Moscow , Ghana , Jordan , We are very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.



  • Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster
    462 Wide Open Throttle (WOT) Position Signal – Diesel Engine Only follow me on twitter https://twitter.com/fupabox



    Multi-turn Three Phase Electric Actuator Operation & Wiring Method.
    Cair Make Multi turn Electric Actuator Three Pahse for valve , gate valve,slide gate damper valve, globe valve, lift valve.

    Electrical Actuator Details:
    Manufacturer: Cair Euromatic Automation Pvt Ltd
    Brand: Cair
    Model: ATM
    Characteristic: On – Off Type
    Power Supply: 415V AC
    Housing & Cover: Cast Iron
    Enclosure: Water Tight IP 67
    Ambient Temperature: -30°C ~ 70°C
    Torque Switches: 2 x SPDT
    Limit Switches: 2 x SPDT
    Stall Protection: Built-in Thermal Protection
    Indicator: Continuous Position Indicator
    Manual Override: Wheel Type
    Torque in Range :- 100nm to 65000nm

    Accessories:
    * Modulating / Regulating Type
    * Input Signal: 4 ~ 20 mA
    * Potentiometer Feedback
    * Integral Starter Unit
    * Control Panel
    * Integral Starter Unit

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck