Renewable Design for TU-1K01 thermal wax actuator for electric switch valve for Netherlands Manufacturers

Renewable Design for
 TU-1K01 thermal wax actuator for electric switch valve for Netherlands Manufacturers

Short Description:

Product Detail

Product Tags

"Control the quality by the details, show the power by quality". Our enterprise has strived to establish a remarkably efficient and stable team team and explored an effective excellent control system for Industrial Wax Manufacturer , Paraffin Wax , Wax Element , We always stick to the principle of "Integrity, Efficiency, Innovation and Win-Win business". Welcome to visit our website and do not hesitate to communicate with us. Are you ready? ? ? Let us go!!!
Renewable Design for TU-1K01 thermal wax actuator for electric switch valve for Netherlands Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Renewable Design for
 TU-1K01 thermal wax actuator for electric switch valve for Netherlands Manufacturers detail pictures


"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for Renewable Design for TU-1K01 thermal wax actuator for electric switch valve for Netherlands Manufacturers, The product will supply to all over the world, such as: Japan , Honduras , Oman , Item have passed by means of the national qualified certification and been well received in our main industry. Our expert engineering team will often be ready to serve you for consultation and feedback. We have been able to also deliver you with cost-free samples to meet your specs. Ideal efforts will probably be produced to deliver you the most beneficial service and solutions. Should really you be interested in our company and solutions, please make contact with us by sending us emails or call us straight away. To be able to know our solutions and enterprise. ar more, you'll be able to come to our factory to see it. We will constantly welcome guests from all over the world to our firm. o build business enterprise. elations with us. You should feel absolutely free to speak to us for organization. nd we believe we are going to share the best trading practical experience with all our merchants.



  • GCS , your Woodward expert in the VariStroke Line Actuator

    The Woodward VariStroke-I is a linear electro-hydraulic actuator that is designed to provide the linear actuation force to operate steam turbine control valves or valve racks. This integrated actuator is intended for use on mechanical-drive or generator drive steam turbines, and uses a low-pressure hydraulic oil source (typically turbine lube oil) to provide its output shaft force.



    Quick tutorial on how to repair your Acura MDX rear air conditioning problem. If you aren’t getting any air/heat in the rear, you might want to watch this video. Works on MDX years 2001-5 + possibly others. More info about how the rear ac works here: https://www.youtube.com/watch?v=BpQU-G-t5So

    You can order a new thermal cutoff here:

    https://www.mouser.com/Search/ProductDetail.aspx?R=EYP-2BN110virtualkey66720000virtualkey667-EYP-2BN110

    *Mouser accepts Paypal*…the part is $2+ more expensive (after shipping) but it had Paypal, so I went with it*

    OR A CHEAPER ONE HERE:

    https://www.digikey.com/product-detail/en/EYP-2BN110/P10921-ND/295817

    *Digikey accepts debit/credit only*

    Thanks to 94eg! for the post here:

    https://www.piloteers.org/forums/14-problems/21634-rear-blower-transistor-fix-6.html

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the House

    WhatsApp Online Chat !