Well-designed TU-1C01 thermal wax actuator for air conditioner and compressor Export to Philippines
Short Description:
Product Detail
Product Tags
Well-designed TU-1C01 thermal wax actuator for air conditioner and compressor Export to Philippines Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for Well-designed TU-1C01 thermal wax actuator for air conditioner and compressor Export to Philippines, The product will supply to all over the world, such as: European , Monaco , Suriname , As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products we offer, effective and satisfying consultation service is supplied by our specialist after-sale service group. Solution lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we are going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.
The Samson Type 3730-3 is an electro-pneumatic valve positioner with HART® communication for use with linear and quarter-turn industrial valves.
The positioner ensures a predetermined assignment of the valve position to the input signal. It compares the input signal received from a control system to the travel or rotational angle of the control valve and issues a corresponding output signal pressure.
Special Features:
Simple attachment to all common linear and rotary actuators with interface for SAMSON direct attachment, NAMUR rib, valves with rod-type yokes according to IEC 60534-6-1 or to rotary actuators according to VDI/ VDE 3845.
Any desired mounting position of the positioner.
Simple single-knob, menu-driven operation.
LCD easy to read in any mounted position due to selectable reading direction.
Configurable with a PC over the SSP interface using the TROVIS-VIEW software.
Variable, automatic start-up with four different initialization modes
Preset parameters – only values deviating from the standard need to be adjusted.
Calibrated travel sensor without gears susceptible to wear.
Sub-initialization mode (substitution) allows the positioner to be started up in case of emergency whilst the plant is running without the valve moving through the whole travel range.
Permanent storage of all parameters in EEPROM (protected against power failure).
Two-wire system with small electrical load between 300 and 350 Ω depending on version.
Adjustable output pressure limitation.
Tight-closing function.
Continuous monitoring of zero point.
Integrated temperature sensor and operating hours counter.
Two standard programmable position alarms.
Self-diagnostics; alarms as condensed state conforming to NAMUR Recommendation NE 107, issued over a fault alarm contact or optional analog position transmitter.
Integrated EXPERTplus diagnostics (u T 8389 EN) suitable for throttling and on/off valves and with additional partial stroke test for valves in safety-instrumented systems.
RENCOR Controls
21 Sullivan Parkway
Fort Edward, NY 12828
Phone: (800) 777- 4174
Fax: (518)747- 4176
Video for Licensed HVAC Professionals ONLY, Please do NOT attempt any Procedures without Professional HVAC Training . (Hazardous)
https://rochesterheatingandair.com please click SHOW more link below
Went to Bryan’s determined he had a bad coil . Carrier informed me they do not make that coil anymore . When Bryan runs this past his wife , I will go back , and retro fit a 2-ton ADP A Coil back into play for him , and his family . This R-22 N coil was a piston coil not a TXV coil . She was plugged pretty good !!!
Rochester Heating & Air Serves the Louisville Kentucky area including but not limited to:
Fern Creek , Middletown , J-town , St. Matthews , Valley Station , PRP , Shively , etc…
Hello ,
I’m Fritz Rochester , a Proud Kentucky Master HVAC Contractor , with over 20 years of experience in the Trade .
I would like to take care of all your HVAC needs . Whether it be a Service Call to get your HVAC System Up and Running Again , or a New HVAC Installation .
Rochester Heating and Air Strives to be one of the Best HVAC Companies in Kentucky .
Tips for hiring Kentucky HVAC Contractors for New HVAC Equipment Installations :
* = Kentucky Law
* Kentucky Master HVAC Contractor (ask to see License)
* Required Insurance (ask for Certificate of Insurance)
* Required Permits (ask for Copy of Permit before Work Begins)
* HVAC Load – Calc on New Construction Homes (ask for Load-Calc)
HVAC Load-Calc is not required at this time on Existing Residential Homes , but I suggest you have one done anyway , by a legitimate HVAC Contractor , I am finding most of our Old HVAC Equipment is OVERSIZED , this will ensure the Proper Sized Equipment for your Home !!!
Please do your Homework and get a Minimum of 3 Bids on your New System Installation , and go with the Contractor you Trust .
Ask your Friends and Family Members who they feel is a Reliable HVAC Contractor ….
(be Very Weary of Buy today for a Significant Savings)
If you have any further questions regarding your New HVAC Installation , or for that matter any HVAC questions regarding your system , Please don’t hesitate to contact me : https://rochesterheatingandair.com
Thanks You very much for watching my videos !!!
Rochester Heating and Air
Fritz Rochester