18 Years Factory offer TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Poland Manufacturers
Short Description:
Product Detail
Product Tags
18 Years Factory offer TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Poland Manufacturers Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:

Our team through professional training. Skilled professional knowledge, strong sense of service, to meet the service needs of customers for 18 Years Factory offer TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Poland Manufacturers, The product will supply to all over the world, such as: Tunisia , Honduras , France , Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to offer our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We are ready to face the worries and make the improve to understand all the possibilities in international trade.
Ideal Boiler Function + Flame Sensor & Gas Ionisation
Some faults below
LE means the control unit is faulty IF it does not clear with power off, wait 10 seconds, then reset and retest.
LF means the control unit did not see a flame, it will try 3 times. No Gas, Faulty Gas Valve, Faulty Spark or electrode in video faulty
LA means Overheat error, possible pump failure or temp sensor.
L8 means Fan Error
H1 means Central Heating ‘flow’ temperature sensor error
H2 means Central Heating flow’Return’ temperature sensor error
H3 means Domestic Hot Water temp sensor error
H4 means Dry Fire temp sensor error
H5 means the jumper pins are in the wrong position or missing
HF Flame Detection error
visit my forum tomplum.boards.net