Factory provide nice price TU-026D thermostatic cartridge wax sensor for sanitary ware for Manufacturers

Factory provide nice price
 TU-026D thermostatic cartridge wax sensor for sanitary ware  for  Manufacturers

Short Description:

Product Detail

Product Tags

Our mission will be to become an innovative supplier of high-tech digital and communication devices by furnishing benefit added structure, world-class manufacturing, and service capabilities for Automatic Home Temperature Control , Automatic Temperature Control Mixing Valve , Thermostatic Faucet , We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Factory provide nice price TU-026D thermostatic cartridge wax sensor for sanitary ware for Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory provide nice price
 TU-026D thermostatic cartridge wax sensor for sanitary ware  for  Manufacturers detail pictures


Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction for Factory provide nice price TU-026D thermostatic cartridge wax sensor for sanitary ware for Manufacturers, The product will supply to all over the world, such as: Puerto Rico , Finland , Malta , Now, we professionally supplies customers with our main merchandise And our business is not only the "buy" and "sell", but also focus on more. We target to be your loyal supplier and long-term cooperator in China. Now, We hope to be the friends with you.



  • Video for Licensed HVAC Professionals ONLY, Please do NOT attempt any Procedures without Professional HVAC Training . (Hazardous)
    http://rochesterheatingandair.com please click SHOW more link below

    Rochester Heating & Air Serves the Louisville Kentucky area including but not limited to:
    Fern Creek , Middletown , J-town , St. Matthews , Valley Station , PRP , Shively , etc…

    Hello ,
    I’m Fritz Rochester , a Proud Kentucky Master HVAC Contractor , with over 20 years of experience in the Trade .
    I would like to take care of all your HVAC needs . Whether it be a Service Call to get your HVAC System Up and Running Again , or a New HVAC Installation .
    Rochester Heating and Air Strives to be one of the Best HVAC Companies in Kentucky .

    Tips for hiring Kentucky HVAC Contractors for New HVAC Equipment Installations :
    * = Kentucky Law
    * Kentucky Master HVAC Contractor (ask to see License)
    * Required Insurance (ask for Certificate of Insurance)
    * Required Permits (ask for Copy of Permit before Work Begins)
    * HVAC Load – Calc on New Construction Homes (ask for Load-Calc)

    HVAC Load-Calc is not required at this time on Existing Residential Homes , but I suggest you have one done anyway , by a legitimate HVAC Contractor , I am finding most of our Old HVAC Equipment is OVERSIZED , this will ensure the Proper Sized Equipment for your Home !!!

    Please do your Homework and get a Minimum of 3 Bids on your New System Installation , and go with the Contractor you Trust .
    Ask your Friends and Family Members who they feel is a Reliable HVAC Contractor ….
    (be Very Weary of Buy today for a Significant Savings)

    If you have any further questions regarding your New HVAC Installation , or for that matter any HVAC questions regarding your system , Please don’t hesitate to contact me : http://rochesterheatingandair.com

    Thanks You very much for watching my videos !!!
    Rochester Heating and Air
    Fritz Rochester



    ***VISIT OUR SPONSORS***
    http://www.traderadiators.com | http://www.grahamplumbersmerchant.co.uk | http://www.buteline.com/uk | http://www.adey.com

    This video covers thermostatic radiator valves. How they work and how you can install them. We also cover which room to install them and why.

    Today, we’re gonna look at thermostatic radiator valves otherwise known as TRVs. They individually control the temperature in the room to an individual radiator. Firstly, we’re gonna have a look at how to change them, and then we’re gonna have a look at how they work. I hope it’s very informative. Hold tight. So, how does a thermostatic radiator valve work, and what’s the difference between that and a normal radiator valve. Well, firstly, a normal radiator valve is just a valve that moves up and down and shuts off the flow of hot water from the boiler into the radiator, just like the tap on a bathtub. The main difference with a thermostatic radiator valve is that it automatically controls the amount of hot water going into a radiator according to the current heat of the room that it’s situated in. There are two main types of thermostatic radiator valve. One uses a spring that expands and contracts, and the other uses a wax jacket that does exactly the same. For this video, we’re gonna look at the spring type, because they both work in a very similar way. So, we have a spring that is made of metal that is very susceptible to the temperature around it. If the room is cold, the metal will be contracted because when metal is cold, it is contracted. Therefore, the valve jumper will be open and hot water will be allowed to flow into the radiator. If the room is warm, the spring will expand and that valve will be pushed down and the flow to the radiator will stop. And that’s how they work. A very common problem I have with customers is, sometimes they’ll come in, the room is cold, the radiator, when they feel it, blazing hot, and yet they still go to the thermostatic radiator valve and open it up more. That’s completely pointless. The room is cold, the radiator’s hot, therefore, the thermostatic radiator valve knows that the room is cold, and it’s trying to heat it up. If you go into a cold room and feel the radiator and it’s hot, do not touch the thermostatic radiator valve. Only touch it when you go into the room, and it’s cold, and you find that the radiator is cold. Also, another thing you need to consider, is where you can actually install thermostatic radiator valves. If you have house with two rooms, in one room you have the room thermostat, which controls the whole heating system, and one radiator. In the other room, you have another radiator and that has a TRV on it. Don’t put a TRV in the room that has the room thermostat in it. The reason for that is, if the TRV closes down, and the room thermostat is not satisfied, it will never knock the heating system off to the whole house, and you won’t get any saving. That room thermostat there needs to have an exactly true reading of the maximum capacity that the heating system can give out. Therefore, the radiator in the room with the room thermostat should have a lock shield on it that is fully open. So let’s go back to the house, and find out how you actually change a lock shield over for a TRV and really how easy they are to install. I’m assuming you all know how to drain down a heating system already. Finding the lowest point in the heating system and drain off, taking your hose outside and opening that up and making sure that the water supply is turned off to the heating system. Next, you allow air into all the radiators that you want to change in the TRVs. Generally, if you’re a bit worried about this, let air into every radiator in the house. You should hear the air sucking. As soon as you see your hose outside stop running, that should indicate that the heating system is drained down and you’re ready to change the valve. Let’s have a look here. As you can see, we’re removing this old lockshield valve here, which is just an on and off valve. So, now that we know the system is all drained down, we can loosen that off. Now’s the time just to make sure that the water has drained out of the system. As you can see it has. And then we can loosen off the 15mm pressure fitting on the bottom. As you can see, our new TRV isn’t going to fit on this current radiator insert. All new TRVs are supplied with a new insert, so this one here will need removing. There are special tools to do this. You can have a hexagonal tool that goes in like that, a square tool, a lug tool cut in here. This is quite an old one as you can see. Today I’m gonna use this one here because we’ve got hexagonal fitting on there. Now often you can just lift out and it may get out. But generally, you’ll have to just put the spanner on like this and then wind it out like that. There’s the old insert out, and that’s the old valve completely removed.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    WhatsApp Online Chat !