Factory Supplier for TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers to Philippines Factories

Factory Supplier for
 TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers to Philippines Factories

Short Description:

Product Detail

Product Tags

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our firm to the long-term to develop together with consumers for mutual reciprocity and mutual advantage for Automation For Temperature Control , Thermal Actuator Thermostatic , Valve Spare Parts , We will supply best quality, the most market competitive price, for every new and old customers with the most perfect green services.
Factory Supplier for TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers to Philippines Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory Supplier for
 TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers to Philippines Factories detail pictures


Dedicated to strict high-quality management and considerate shopper company, our experienced team associates are normally available to discuss your requirements and ensure full shopper gratification for Factory Supplier for TU-1F90 thermal wax actuator for automobile engine thermostat manufacturers to Philippines Factories, The product will supply to all over the world, such as: Doha , Afghanistan , Accra , Today, We are with great passion and sincerity to further fulfill our global customers' needs with good quality and design innovation. We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.



  • Ideal Boiler Function + Flame Sensor & Gas Ionisation
    Some faults below
    LE means the control unit is faulty IF it does not clear with power off, wait 10 seconds, then reset and retest.
    LF means the control unit did not see a flame, it will try 3 times. No Gas, Faulty Gas Valve, Faulty Spark or electrode in video faulty
    LA means Overheat error, possible pump failure or temp sensor.
    L8 means Fan Error
    H1 means Central Heating ‘flow’ temperature sensor error
    H2 means Central Heating flow’Return’ temperature sensor error
    H3 means Domestic Hot Water temp sensor error
    H4 means Dry Fire temp sensor error
    H5 means the jumper pins are in the wrong position or missing
    HF Flame Detection error



    The above animation shows how a Horne thermostatic mixing valve or TMV works to proportion the mix of hot and cold water to provide blended water at a set temperature. The expansion and contraction of the internal thermostatic element moves a slide valve – altering the aperture of the hot and cold inlet ports to the inner mixing chamber thus constantly adjusting the blend of hot and cold water.

    Thermostatic performance of the TMV can be verified by conducting a Cold Water Failure Test as shown in the animation: gradual failure of the cold water supply causes the thermostatic element to expand fully as it becomes increasingly bathed in hot water. This expansion moves the slide valve to the fully closed position over the hot port and thus flow at the outlet ceases. If the flow does not reduce to a dribble, then maintenance may be required to restore the valve to optimal performance.