Free sample for TU-1C03 thermal wax actuator for industrial adjustable temperature switch control Export to Iraq

Free sample for
 TU-1C03 thermal wax actuator for industrial adjustable temperature switch control Export to Iraq

Short Description:

Product Detail

Product Tags

We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for Energe Wax Suppliers , Air Compressor Pressure Switch , Sensing Wax , Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software development are our distinguishing feature.
Free sample for TU-1C03 thermal wax actuator for industrial adjustable temperature switch control Export to Iraq Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

Free sample for
 TU-1C03 thermal wax actuator for industrial adjustable temperature switch control Export to Iraq detail pictures


Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Free sample for TU-1C03 thermal wax actuator for industrial adjustable temperature switch control Export to Iraq, The product will supply to all over the world, such as: Australia , Southampton , Sudan , With many years good service and development, we have a qualified international trade sales team. Our goods have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!



  • Horizon How-To: Changing Your Programmable Thermostat Batteries

    Programmable control centers or thermostats such as this Honeywell VisionPRO 8000 are great system accessories that allow homeowners to have complete control over their heating and cooling systems. They allow the user to manually adjust the temperature of their home at the push of a button or to set up an automatic schedule that will ensure their system operates at peak efficiency to save them money.

    Simple dial or switch controlled thermostats may never require batteries for operation but almost all modern digital programmable control centers will.

    Possible signs that you need to replace your thermostat batteries include a low battery warning on the thermostat’s display, unusual behavior from your heating or cooling system, or an unresponsive thermostat screen.

    If your Honeywell VisionPRO 8000 thermostat displays a blank or unresponsive screen, or a low battery indicator you will need to replace the batteries. This can be accomplished by removing the faceplate of the thermostat by depressing the top release button marked PRESS and lifting the unit out and away.

    Turn the thermostat over to reveal the old batteries. This model requires 4 AA batteries but your control center may vary. Once your new batteries have been installed, hold the thermostat at an angle and insert the two latches into the bottom of the wall mount. Finish your reinstallation by snapping the unit securely into place.

    To avoid any interruption in your system’s operation, we recommend being proactive and changing the batteries in your thermostat at least once a year. It is always a good practice to install new batteries on the same schedule as your smoke alarm and carbon monoxide detector to ensure these vital components of your home are fully powered.

    Learn more about the plumbing, heating, and air conditioning services we offer at HorizonServices.com or by calling 1-800-999-1995.

    © 2015 By Horizon Services, Inc. All Rights Reserved. DE License # PL0000726, HL0000299. Contractor Reg. # PA017876, PA057742. NJ HVACR Lic. # 19370, M-PL Lic. # 12323 – David Geiger. MD Master HVACR contractor Lic. # 47186, Master Plumber Lic. # 63739 – David Geiger.



    Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster
    462 Wide Open Throttle (WOT) Position Signal – Diesel Engine Only follow me on twitter https://twitter.com/fupabox