China Professional Supplier TU-1A93 thermal wax actuator for thermostatic automatic water drain valve to Tunisia Factory

China Professional Supplier
 TU-1A93 thermal wax actuator for thermostatic automatic water drain valve to Tunisia Factory

Short Description:

Product Detail

Product Tags

We continue to keep increasing and perfecting our solutions and service. At the same time, we operate actively to do research and enhancement for Air Compressor Thermostatic Valve , Chrome Radiator Valves , Thermostatic Radiator Valve , We can do your customized order to meet your own satisfactory! Our company sets up several departments, including production department, sales department, quality control department and sevice center, etc.
China Professional Supplier TU-1A93 thermal wax actuator for thermostatic automatic water drain valve to Tunisia Factory Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

China Professional Supplier
 TU-1A93 thermal wax actuator for thermostatic automatic water drain valve to Tunisia Factory detail pictures


Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of China Professional Supplier TU-1A93 thermal wax actuator for thermostatic automatic water drain valve to Tunisia Factory, The product will supply to all over the world, such as: Casablanca , Bangladesh , Turkey , Upon today, we have customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the highest quality products with best price. We are looking forward to doing business with you.




  • Code
    #include 16f877a.h
    #device adc=10 // Set ADC resolution to 10Bit
    #fuses XT,NOLVP,NOWDT,NOPROTECT
    #use delay(clock=4000000)
    #use rs232(baud=9600,xmit=PIN_C6,rcv=PIN_C7,ERRORS)
    #include “flex_lcd.c”

    #define LOAD PIN_B7
    #define THRES 30.0 // load switching threshold in Celsius

    int16 digital_reading; // ADC resolution is 10Bit, an 8Bit integer is not enough to hold the reading
    float temp;

    void main()

    /* ADC Initialization */
    setup_adc(ADC_CLOCK_INTERNAL); // initialize ADC with a sampling rate of Crystal/4 MHz
    setup_adc_ports(RA0_ANALOG); // set PIN_A0 as analog input channel
    set_adc_channel(0); // point ADC to channel 0 for ADC reading
    delay_ms(1); // ADC module is slow, needs some time to adjust.

    /* Peripherals Configurations */
    lcd_init(); // Turn LCD ON, along with other initialization commands
    output_low(LOAD); // the load is initially OFF
    lcd_gotoxy(1,1); // point LCD cursor to col1 row1
    lcd_putc(“Temperature is:”); // print on LCD

    while(1) // infinite loop

    digital_reading = read_adc(); // capture current temperature reading
    delay_us(100); // 0.1ms delay for ADC stabilization
    temp = digital_reading * 0.4883; // convert reading to Celsius
    lcd_gotoxy(1,2); // point LCD cursor to col1 row2
    printf(lcd_putc,”%2.1f C”,temp); // print value on LCD

    if(temp=THRES) output_high(LOAD); // Control Load
    else output_low(LOAD);

    delay_ms(1000); // 1 second delay between readings